Depth of interaction determination in monolithic scintillator with double side SiPM readout

نویسندگان

  • Matteo Morrocchi
  • Giovanni Ambrosi
  • Maria Giuseppina Bisogni
  • Filippo Bosi
  • Marco Boretto
  • Piergiorgio Cerello
  • Maria Ionica
  • Ben Liu
  • Francesco Pennazio
  • Maria Antonietta Piliero
  • Giovanni Pirrone
  • Vasile Postolache
  • Richard Wheadon
  • Alberto Del Guerra
چکیده

BACKGROUND Monolithic scintillators read out by arrays of photodetectors represent a promising solution to obtain high spatial resolution and the depth of interaction (DOI) of the annihilation photon. We have recently investigated a detector geometry composed of a monolithic scintillator readout on two sides by silicon photomultiplier (SiPM) arrays, and we have proposed two parameters for the DOI determination: the difference in the number of triggered SiPMs on the two sides of the detector and the difference in the maximum collected signal on a single SiPM on each side. This work is focused on the DOI calibration and on the determination of the capability of our detector. For the DOI calibration, we studied a method which can be implemented also in detectors mounted in a full PET scanner. We used a PET detector module composed of a monolithic 20 × 20 × 10 mm3 LYSO scintillator crystal coupled on two opposite faces to two arrays of SiPMs. On each side, the scintillator was coupled to 6 × 6 SiPMs. In this paper, the two parameters previously proposed for the DOI determination were calibrated with two different methods. The first used a lateral scan of the detector with a collimated 511 keV pencil beam at steps of 0.5 mm to study the detector DOI capability, while the second used the background radiation of the 176Lu in the scintillator. The DOI determination capability was tested on different regions of the detector using each parameter and the combination of the two. RESULTS With both parameters for the DOI determination, in the lateral scan, the bias between the mean reconstructed DOI and the real beam position was lower than 0.3 mm, and the DOI distribution had a standard deviation of about 1.5 mm. When using the calibration with the radioactivity of the LYSO, the mean bias increased of about 0.2 mm but with no degradation of the standard deviation of the DOI distribution. CONCLUSIONS The two parameters allow to achieve a DOI resolution comparable with the state of the art, giving a continuous information about the three-dimensional interaction position of the scintillation. These results were obtained by using simple estimators and a detector scalable to a whole PET system. The DOI calibration obtained using lutetium natural radioactivity gives results comparable to the other standard method but appears more readily applicable to detectors mounted in a full PET scanner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel, SiPM-array-based, monolithic scintillator detector for PET.

Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-se...

متن کامل

A practical depth-of-interaction PET/MR detector with dichotomous-orthogonal-symmetry decoding

University of Texas MD Anderson Cancer Center, Houston, Texas, USA Conventional dual-end depth-of-interaction (DOI) PET detector readout requires two 2D SiPM arrays; with top and bottom SiPM reading the same pixel, there is information redundancy. We proposed a dichotomous-orthogonal-symmetric (DOS) dual-end DOI readout to eliminate this redundancy to significantly reduce SiPM usage, electronic...

متن کامل

SiPM-MAROC gamma-camera prototype with monolithic NaI(Tl) scintillator.

National Research Nuclear University, Moscow Engineering Physics Institute, Russia A full-body gamma-camera based on SiPM readout is currently under development as a part of MEPHI R activity supported in the framework of Russian Megagrants program. A goal of this development is a fast upgrade of existing medical equipment with minor changes in a system design and construction in order to combin...

متن کامل

3D photon impact determination in monolithic crystals based on autocorrelation filters and RTP methods

Institute for Instrumentation in Molecular Imaging, I3M-CSIC, Valencia, Spain In PET detectors based on monolithic scintillators, the photon impact position can be estimated from the light intensity distribution (LD) on the photodetector pixels. Typically, there is a poor estimation of the interaction positions towards the edges when linear algorithms such as Center of Gravity (CoG) are used. W...

متن کامل

Development of high-resolution detector module with depth of interaction identification for positron emission tomography

We have developed a Time-of-flight high resolution and commercially viable detector module for the application in small PET scanners. A new approach to depth of interaction (DOI) encoding with low complexity for a pixelated crystal array using a single side readout and 4-to-1 coupling between scintillators and photodetectors was investigated. In this method the DOI information is estimated usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017