Catchlike property of rat diaphragm: subsequent train frequency effects in variable-train stimulation.

نویسندگان

  • E van Lunteren
  • C B Sankey
چکیده

A high-frequency burst of pulses at the onset of a subtetanic train of stimulation allows skeletal muscle to hold force at a higher level than expected from the extra pulses alone because of the catchlike property of muscle. The present study tested the hypothesis that the presence and degree of force increase induced by a high-frequency burst are strongly modulated by the subsequent train frequency. Rat diaphragm muscle strips (studied in vitro at 37 degrees C) underwent two-, three-, or four-pulse bursts [interpulse interval (IPI) of 5 or 10 ms] at the onset of 10- to 50-Hz subtetanic trains. Force was quantified during the train with respect to its peak value (F(peak)), mean value (F(mean)), and force-time integral (F(area)), and it was compared with that produced during subtetanic trains of an equal number of pulses without preceding pulse bursts (Diff-F(peak), Diff-F(mean), Diff-F(area)). F(peak) and F(mean) increased with two-, three-, and four-pulse bursts, and Diff-F(peak) and Diff-F(mean) increased progressively with decreasing frequency of the subtetanic train. F(area), the best reflection of catchlike force augmentation, was increased mainly by the four-pulse bursts with an IPI of 10 ms, and Diff-F(area) was maximal at subsequent train frequencies of 15-25 Hz. The use of incorrect patterns of burst stimulation could also precipitate F(area) decreases, which were observed with the four-pulse, 5-ms IPI paradigm. The time required to reach 80% of maximal force (T(80%)) became shorter for each of the pulse burst stimulation patterns, with maximal reduction of Diff-T(80%) occurring at a subsequent train frequency of 20 Hz in all cases. These data indicate that extra-pulse burst stimulation paradigms need to incorporate the optimal combinations of extra-pulse number, IPI, and the frequency of the subsequent subtetanic train to take greatest advantage of the catchlike property of muscle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of length on the catchlike property of human quadriceps femoris muscle.

BACKGROUND AND PURPOSE Recent reports have suggested that electrical stimulation trains that take advantage of the catchlike property of skeletal muscle can produce higher forces from skeletal muscle than traditionally used constant-frequency trains. This study investigated the effects of catchlike-inducing trains on human quadriceps femoris muscles while the kneejoint was held at 15 degrees of...

متن کامل

Effects of activation pattern on nonisometric human skeletal muscle performance.

During volitional muscle activation, motor units often fire with varying discharge patterns that include brief, high-frequency bursts of activity. These variations in the activation rate allow the central nervous system to precisely control the forces produced by the muscle. The present study explores how varying the instantaneous frequency of stimulation pulses within a train affects nonisomet...

متن کامل

Catchlike-inducing train activation of human muscle during isotonic contractions: burst modulation.

Stimulation trains that exploit the catchlike property [catchlike-inducing trains (CITs)] produce greater forces and rates of rise of force than do constant-frequency trains (CFTs) during isometric contractions and isovelocity movements. This study examined the effect of CITs during isotonic contractions in healthy subjects. Knee extension was electrically elicited against a load of 10% of maxi...

متن کامل

Variable-frequency train stimulation of canine latissimus dorsi muscle during shortening contractions.

In cardiomyoplasty, the latissimus dorsi muscle (LDM) is wrapped around the heart ventricles and electrically activated with a constant-frequency train (CFT). This study tested the hypotheses that increased mechanical performance from the LDM could be achieved by activating the muscle with variable-frequency trains (VFTs) of shorter duration or containing fewer stimulus pulses than the CFT now ...

متن کامل

Effect of phasic activation on endplate potential in rat diaphragm.

Neuromuscular junction endplate potentials (EPPs) decrease quickly and to a large extent during continuous stimulation. The present study examined the hypothesis that EPP rundown recovers rapidly, thereby substantially preserving neurotransmission during intermittent compared with continuous stimulation. Studies were performed in vitro on rat diaphragm, using mu-conotoxin to allow recording of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 88 2  شماره 

صفحات  -

تاریخ انتشار 2000