Performance of Nonlinear Visual Units in Ocular Hypertension and Glaucoma
نویسندگان
چکیده
!. Two psychophysical tests to assess retinal function in ocular hypertension and glaucoma are described. The basis for these tests is the frequency-doubled percept seen with rapid temporal modulation of the contrast of very low spatial frequencies. 2. The results of the second set of experiments show correlation (P < 0.01) with optic disc cupping. Without the inclusion of information about subjects' optic disc condition the second experimental procedure distinguishes the test group from normals (P < 0.01). 3. A model which considers optic disc condition in conjunction with the results of the main experimental method described leads to a separability of normals and a subgroup with moderate disc cupping at the P < 0.001 level. 4. The results reported here, taken together with the current data on retinal ganglion cell function, indicate that harnessing unique features of the frequency-doubled illusion may allow the design of a highly specific and sensitive test for the assessment of early glaucomatous damage.
منابع مشابه
Rho Kinase Inhibitors as a Novel Treatment for Glaucoma and Ocular Hypertension
In an elegant example of bench-to-bedside research, a hypothesis that cells in the outflow pathway actively regulate conventional outflow resistance was proposed in the 1990s and systematically pursued, exposing novel cellular and molecular mechanisms of intraocular pressure (IOP) regulation. The critical discovery that pharmacologic manipulation of the cytoskeleton of outflow pathway cells dec...
متن کاملمقایسه تاثیر تیمولول و بتاکسولول بر کاهش فشار داخل چشمی و عوارض موضعی و سیستمیک آنها
Background and purpose: This is a study to compare the efficacy and side effects of betaxolol and timolol in lowering the IOP of primary open angle glaucoma or ocular hypertension. Materials and Methods: This Double-blind randomized cross-over clinical trial was conducted on 29 eyes of 20 patients with primary open angle glaucoma or ocular hypertension. Each patient received timolol 0.5% a...
متن کاملMotion automated perimetry identifies early glaucomatous field defects.
OBJECTIVE To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n...
متن کاملCentral visual fields for short wavelength sensitive pathways in glaucoma and ocular hypertension.
While conventional clinical visual acuity and kinetic visual fields may be essentially normal in ocular hypertension and early stages of glaucoma, other foveal aspects of vision (eg color, spatial and temporal contrast sensitivity) may be quite abnormal. Specifically, a selective vulnerability of the short wavelength sensitive (SWS) visual pathways in these conditions has previously been noted....
متن کاملThe Relationship Between Self-Management and Quality of Life and Visual Function in Glaucoma Patients
Introduction: Self-management positively contributes to the Quality of Life of many patients with chronic diseases. Objective: The present study aimed to investigate the relationship between self-management and the quality of life and visual performance among patients with glaucoma. Materials and Methods: The current cross-sectional and comparative study was conducted at the...
متن کامل