Variability in the LAL test: comparison of three kinetic methods for the testing of pharmaceutical products.

نویسندگان

  • K Z McCullough
  • C Weidner-Loeven
چکیده

Data presented in this study indicate that there is considerable variability in spike recoveries between three different kinetic LAL methods as used for the testing of a variety of parenteral products. However, successful spike recoveries were observed for each of the thirteen products under test on at least one of the three kinetic methods used, suggesting that problems caused by spike recovery variability may be easily controlled in the laboratory by flexibility in the choice of method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of LAL test on some antibiotics: A study on the causes of different inhibitory effects

Validation process is a program for ensuring products with proven acceptable and predetermined specification. The LAL test used for detection of endotoxin in the sterile parenteral products is one of the tests that require validation. During this study, validation of 12 parenteral antibiotics including penicillin and cephalosporin have been done using gel clot method and obtained results which ...

متن کامل

Assessing Assessment Literacy: Insights From a High-Stakes Test

This study constitutes an attempt to see what Language assessment literacy (LAL) isfor three groups of stakeholders, namely LAL test developers, LAL instructors, andLAL test-takers. The perceptions of the former group were derived from the contentanalysis of the latest version of the LAL test, and those of the latter 2 groups wereassessed through a survey designed by the researcher. Participant...

متن کامل

Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test

The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...

متن کامل

Iranian EFL Teachers' Language Assessment Literacy (LAL) under an ‎Assessing Lens

Despite being trained in pre-service teacher education programs, most EFL teachers are underprepared when faced with language assessment-related activities. Part of the problem emanates from the fact that Language Assessment Literacy (LAL) as a construct has not been well defined by experts. The purpose of this study was to pinpoint the components of LAL in the Iranian EFL context using an adap...

متن کامل

BP-ANN Approach for Modeling Cd(II) Bio-Sorption from Aqueous Solutions Using Cajanus cajan Husk

This work aims at the modeling of bio-sorption of cadmium(II) onto physically and chemically activated Cajanus cajan (Pigeon pea) husks. Experimental data obtained were fitted to a number of isotherm and kinetic models, and the results interpreted. The monolayer Cd(II) bio-sorption capacities of the husk were found to considerably increase by 2.82 times due to chemical activation, for bio-s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of parenteral science and technology : a publication of the Parenteral Drug Association

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 1992