HVDC Transmission with STATCOM
نویسنده
چکیده
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these case, the consideration was the converter transformer saturation, which results in voltage and current distortion at the inverter end and Rectifier End. Results with certain fault cases-with either 1-phase, 3-phase and Dc fault at the inverter end and rectifier end are presented. (i.e., taken from CIGRE model) Power Quality analyzed both at rectifier and inverter end after the fault and the types of fault taken in to considerations are: 1) L-G fault, 2) L-L-G fault, 3) DC fault. This should be compared where the corresponding case with the STATCOM in place is depicted. In this project work, a HVDC transmission line from CIGRE model sending end and receiving end power having 100MVA. The DC line is approximately 100 km long and is connected to the 100MVA system through two converter transformers, one of them with wye (grounded)/delta configuration, and the other with delta / wye (grounded) configuration at each end, from the simulation results, it has been shown that the voltage profile analysis can be done by using PSCAD/EMTDC software.
منابع مشابه
DC Fault Ride-through Capability and STATCOM Operation of a HVDC Hybrid Voltage Source Converter
HVDC transmission systems are becoming increasingly popular when compared to conventional AC transmission methods. HVDC voltage source converters (VSC) can offer advantages over traditional HVDC current source converter topologies; as such, it is expected that HVDC-VSCs will be further exploited with the growth of HVDC transmission. This paper presents the DC fault ride through capability and n...
متن کاملPerformance of Hybrid Reactive Power Compensators in a Multi-terminal Hvdc Transmission System Feeding Weak Ac Networks during Transient Fault Conditions
In this paper performance analysis of various hybrid reactive power compensators (RPC’s) at the inverter AC sides of a line commutated converter (LCC) based multi-terminal HVDC (MTDC) transmission system, feeding weak AC networks, is carried out to thoroughly gather the mechanisms of interactions between an HVDC system and weak AC systems. The hybrid compensator is realized by equally mixing th...
متن کاملPerformance Investigation of a Monopolar HVDC Transmission System Feeding a Weak AC Network
This paper investigates the performance of line commutated converter (LCC) based monopolar HVDC transmission system feeding a weak AC network with hybrid reactive power compensators (RPC’s) at the inverter AC side. The hybrid compensator is an equal mix of any two of the following compensators: synchronous compensator (SC); static var compensator (SVC); static synchronous compensator (STATCOM)....
متن کاملAnalysis of Multi-terminal Hvdc Transmission System Feeding Very Weak Ac Networks
This paper presents a line commutated converter (LCC) based multi-terminal HVDC transmission (MTDC) system feeding very weak AC networks with hybrid reactive power compensators (RPC’s) at the inverter AC side. The hybrid compensator is accomplished by the equal mixing of any two of the following compensators: synchronous compensator (SC); static var compensator (SVC); static synchronous compens...
متن کاملSimulation Study of Dynamic Fault Recovery Performance of VSC-HVDC System
The fault recovery of VSC-HVDC transmission system is often influenced by many factors, such as the reactive power compensation characteristics of the inverter and the dynamic performance of DC controllers. In this paper, the PSCAD/ EMTDC simulation tool is used to study the dynamic recovery performance of VSC-HVDC system for several different var compensating devices in VSC-HVDC inverter-Fixed...