The Relationship between Electrical Axis by 12-Lead ECG and Anatomical Axis of the Heart by CMR in Healthy Subjects Short title: Electrical vs anatomical heart axis

نویسندگان

  • Henrik Engblom
  • John E. Foster
  • Thomas N. Martin
  • Bjoern Groenning
  • Olle Pahlm
  • Henry J. Dargie
  • Galen S. Wagner
  • Håkan Arheden
چکیده

Background: The traditional assumption has been that there is a close relationship between the electrical and anatomical axes of the heart. The aim of this study was to test the hypothesis that there is a correlation between the electrical and anatomical axes of the heart, in both the frontal and transverse planes, in healthy subjects. Methods: Ninety-four healthy volunteers (48 males, 46 females; age, 21-82 years) were studied by cardiac magnetic resonance (CMR) and 12-lead ECG. The anatomical axis was determined by CMR and projected onto the frontal and transverse orthogonal planes for comparison with the electrical axis in the corresponding planes. Results: The electrical and anatomical axes were in the same range in the frontal plane (+39 ± 31° and +38 ± 10°, mean ± SD), but in different ranges in the transverse plane (-30 ± 18° and +46 ± 7°, mean ± SD). The partial correlation coefficients between electrical and anatomical axes was r = 0.30 (p < 0.01) and r = 0.14 (p = NS) in the frontal and transverse planes, respectively. Age was more strongly correlated to electrical axis than to anatomical axis in the frontal plane. Conclusions: There is only a weak correlation between electrical and anatomical axes in the frontal plane and no correlation in the transverse plane. The change of electrical axis with increased age is not explained only by change in the anatomical axis. The results suggest that there is no simple relationship between the electrical and anatomical axes of the heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Effects of tramadol on electrocardiogram, mean electrical axis and respiration in Kagani goats (Capra hircus)

The effects of tramadol on electrocardiogram (ECG), mean electrical axis and respiratory rates were studied in adult kagani goats after intramuscular administration of tramadol at 1 mg/kg b.wt. as a prelude to its clinical use as an analgesic in veterinary practice. The ECG was monitored by standard bipolar leads and discernible electrocardiographic features were observed in lead II. The normal...

متن کامل

A Survey on Electrocardiographic Parameters in Broiler Chickens Following the Intracerebroventricular Injection of Melatonin

Objective- The pineal gland and its principal hormone melatonin play an important role in the circadian organization in birds. However, little is known about the role of melatonin in cardiac activity of broiler chicken. The aim of this study was to assess the impact of intracerebroventricular injection of melatonin in electrocardiographic parameters, heart rate and mean electri...

متن کامل

Radiographic Measurement of Vertebral Heart Scale (VHS) in New Zealand White Rabbits

Objective- The aim of the present survey was to evaluate whether the results of cardiac measurements using the VHS are a useful indicator of the origin of normal rabbits. Design- Experimental study. Animals- Forty seven adult healthy New Zealand White rabbits (25 male, 22 female) with age 10-18 months and weight 1.5-2.5 Kg. Procedures- To assess the influence of breed on the vertebral heart ...

متن کامل

The Pituitary-Thyroid Axis in Acromegaly

The pituitary-Thyroid axis of 12 Acromegalic patients was evaluated by measurement of the concentration (Total and free of thyroxine T4, T3 and revers T3 (rT3) and TSH, GH and prolactin before and after in stimulation with TRH. Using an ultra­sensitive method of TSH measurement (IRMA) basal serum TSH levels of patients (0.76, 0.07-l.90mlU/L) were found slightly but significantly (P < 0.01), low...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005