Quantitative in-line phase-contrast imaging with multienergy X rays.

نویسندگان

  • T E Gureyev
  • S Mayo
  • S W Wilkins
  • D Paganin
  • A W Stevenson
چکیده

We present a new method for quantitative nondestructive characterization of objects by x-ray phase-contrast imaging. Spatial distributions of the projected values of the complex refractive index in the sample are reconstructed by processing near-field images collected at a fixed sample-to-detector distance using a polychromatic incident beam and an energy-sensitive area detector, such as a CCD used in the photon-counting spectroscopy mode. The method has the potential advantages of decreased radiation dose and increased accuracy compared to conventional techniques of x-ray imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hard x-ray quantitative non-interferometric phase-contrast microscopy

We report the results of quantitative phase-contrast imaging experiments using synchrotron radiation, in-line imaging geometry and a non-interferometric phase retrieval technique. This quantitative imaging method is fast, simple, robust, does not require sophisticated x-ray optical elements and can potentially provide submicron spatial resolution over a field of view of the order of centimetres...

متن کامل

X-ray phase-contrast microscopy and microtomography.

In-line phase contrast enables weakly absorbing specimens to be imaged successfully with x-rays, and greatly enhances the visibility of fine scale structure in more strongly absorbing specimens. This type of phase contrast requires a spatially coherent beam, a condition that can be met by a microfocus x-ray source. We have developed an x-ray microscope, based on such a source, which is capable ...

متن کامل

Characterization of an x-ray phase contrast imaging system based on the miniature synchrotron MIRRORCLE-6X.

PURPOSE The implementation of in-line x-ray phase contrast imaging (PCI) for soft-tissue patient imaging is hampered by the lack of a bright and spatially coherent x-ray source that fits into the hospital environment. This article provides a quantitative characterization of the phase-contrast enhancement of a PCI system based on the miniature synchrotron technology MIRRORCLE-6X. METHODS The p...

متن کامل

Quantitative phase imaging with a scanning transmission x-ray microscope.

We obtain quantitative phase reconstructions from differential phase contrast images obtained with a scanning transmission x-ray microscope and 2.5 keV x rays. The theoretical basis of the technique is presented along with measurements and their interpretation.

متن کامل

Geometry-constraint-scan imaging for in-line phase contrast micro-CT.

X-ray phase contrast computed tomography (CT) uses the phase shift that x-rays undergo when passing through matter, rather than their attenuation, as the imaging signal and may provide better image quality in soft-tissue and biomedical materials with low atomic number. Here a geometry-constraint-scan imaging technique for in-line phase contrast micro-CT is reported. It consists of two circular-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 86 25  شماره 

صفحات  -

تاریخ انتشار 2001