The dynamic relationship between end-tidal sevoflurane concentrations, bispectral index, and cerebral state index in children.

نویسندگان

  • Ricardo Fuentes
  • Luis I Cortínez
  • Michel M R F Struys
  • Alejandro Delfino
  • Hernán Muñoz
چکیده

BACKGROUND To guide anesthetic administration with electroencephalogram monitors in children, an adequate characterization of the anesthetic effect measured by these monitors in this population is needed. We sought to quantify and compare the dynamic profile of sevoflurane's effect measured with the cerebral state index (CSI) and the bispectral index (BIS) in children. METHODS Fifteen healthy children, aged 3-15 yr, scheduled to undergo minor surgery were prospectively studied. During the simultaneous recording of CSI and BIS, the sevoflurane vaporizer was set at 6 vol % for 5 min and then decreased. End-tidal concentrations (C(ET)) were measured. The C(ET)-sevoflurane effect-site concentration equilibration and pharmacodynamics were modeled. Goodness of fit between models was compared. Data are typical value (coefficient of variation). RESULTS Within the anesthetic depth range studied, the rate of change of sevoflurane's effect expressed as the effect-site equilibration half-life (t(1/2) k(e0)) was slower with the CSI [2.0 (14) min] than with BIS [1.2 (53) min] (P < 0.05). The estimated baseline effect of BIS and CSI before sevoflurane administration (E(0)) was 84 (39) for CSI and 87 (7) for BIS (NS). The sensitivity to sevoflurane hypnotic effect expressed in the C(50) [steady-state C(ET) eliciting half of the maximum response (E(max))] was 2.1 (68) % with CSI and 2.1 (16)% with BIS (NS). The E(max) with CSI 45 (0) was higher than that with BIS 27 (39) (P < 0.05). The population prediction error was significantly better for BIS (-0.7 +/- 26.9) than for CSI (-3.0 +/- 178.6) (P < 0.05). CONCLUSIONS In children, the t(1/2) k(e0) of sevoflurane and the pharmacodynamics of sevoflurane were quantified and the results were entirely dependent on the monitor used to measure its hypnotic effect. Within the anesthetic depth range studied, the rate of change of sevoflurane's effect was slower with the CSI. To adequately guide sevoflurane administration with these monitors in children, these differences should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of age on hypnotic requirement, bispectral index, and 95% spectral edge frequency associated with sedation induced by sevoflurane.

BACKGROUND Aging is associated with a reduction in anesthetic requirements. The effects of age on the electroencephalographic response to inhalational anesthesia have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and electroencephalographic derivatives such as bispectral index and 95% spectral edge frequency associated...

متن کامل

The effect of dexmedetomidine on bispectral index monitoring in children.

The primary aim of this study was to test whether dexmedetomidine administration based on the bispectral index (BIS) monitoring caused a reduction in consumption of sevoflurane. Following Institutional Ethic Committee approval and written informed consent from all parents, fifty-four children undergoing sevoflurane anaesthesia randomly allocated to receive either dexmedetomidine (Group D) or sa...

متن کامل

Pediatric evaluation of the bispectral index (BIS) monitor and correlation of BIS with end-tidal sevoflurane concentration in infants and children.

UNLABELLED The bispectral index (BIS) has been developed in adults and correlates well with clinical hypnotic effects of anesthetics. We investigated whether BIS reflects clinical markers of hypnosis and demonstrates agent dose-responsiveness in infants and children. In an observational arm of this study, BIS values in children undergoing general anesthesia were observed and compared with simil...

متن کامل

Correlation of bispectral index with end-tidal sevoflurane concentration and age in infants and children.

BACKGROUND The bispectral index (BIS) has been evaluated as a tool for measuring depth of anaesthesia, but the use of BIS in a paediatric population is still controversial. This study was designed to evaluate the correlation of BIS with end-tidal sevoflurane concentration and age in infants and children. METHODS Eighty-one patients undergoing elective urology surgery were allocated into three...

متن کامل

Advance of age decreases the minimum alveolar concentrations of isoflurane and sevoflurane for maintaining bispectral index below 50.

BACKGROUND We investigated age-related differences in the minimum alveolar concentration (MAC) of isoflurane and sevoflurane for maintaining bispectral index (BIS) below 50 (MAC(BIS50)). METHODS One hundred and twenty young (or=70 yr) patients were randomly allocated to one of the six groups. Anaesthesia was induced with isoflurane or sevoflur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 107 5  شماره 

صفحات  -

تاریخ انتشار 2008