Title : 2 D THERMAL RESISTANCE OF PILE HEAT EXCHANGERS

نویسندگان

  • Fleur Loveridge
  • William Powrie
چکیده

Structural foundation piles are being used increasingly as heat exchangers to provide renewable heat for new buildings. To design such energy systems a steady state is assumed within the pile, which is conventionally characterised by constant thermal resistance. However, there has been little research regarding pile resistance and there are few published case studies. Numerical modelling results are presented here to provide typical values of pile resistance, depending on the details of the heat exchange pipes. Analysis suggests large diameter piles may take several days to reach steady state; in these cases a transient design approach may be more appropriate. (100 words)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

G-Functions for Multiple Interacting Pile Heat Exchangers

Pile heat exchangers – where heat transfer pipes are cast into the building piled foundations – offer an opportunity to use ground energy systems without the additional construction costs related to the provision of special purpose heat exchangers. However, analysis methods for pile heat exchangers are still under development. In particular there is an absence of available methods and guidance ...

متن کامل

Thermal Design Considerations and Performance Evaluation of Cryogenic Tube in Tube Heat Exchangers

Heat exchangers are the most important equipment in refrigeration processes. Design and modeling of heat exchangers operating at low temperatures are different from other regular heat exchangers. This study includes two sections. In the first section, design and modeling considerations needed for evaluating the real thermal behavior of heat exchangers at low temperatures were discussed. The...

متن کامل

Improvement in Modeling of Heat Transfer in Vertical Ground Heat Exchangers

The heat transfer model of vertical ground heat exchangers for ground-source heat pump systems is discussed. An explicit solution of a finite line-source model has been derived to better describe temperature response of boreholes for long time steps, which can be easily incorporated into computer programs for thermal analysis of ground heat exchangers. A quasi-three-dimensional model is also pr...

متن کامل

Assessing the Applicability of Thermal Response Testing to Energy Piles

Deep foundations are increasingly being used, not just to carry structural loads, but also to act as heat exchangers as part of a ground source heat pump system. Such foundations, often called energy piles, have the potential to make significant contributions towards meeting the heating and cooling demands of buildings, thus reducing the overall energy consumption and carbon dioxide emissions d...

متن کامل

Structural Behaviour of Concrete Energy Piles in Thermal Loadings

The thermo-mechanical behaviour of concrete energy pile foundations with different single and double U-tube shapes incorporated was analysed using the Comsol Multi-physics package. For the analysis, a 3D numerical model in real scale of the concrete pile and surrounding soil was simulated regarding actual operation of ground heat exchangers (GHE) and the surrounding ambient temperature. Based o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014