Comparison of Ethnic-specific Databases in Heidelberg Retina Tomography-3 to Discriminate Between Early Glaucoma and Normal Chinese Eyes

نویسندگان

  • Xiu Ling Tan
  • Sae Cheong Yap
  • Xiang Li
  • Leonard W. Yip
چکیده

PURPOSE To compare the diagnostic accuracy of the 3 race-specific normative databases in Heidelberg Retina Tomography (HRT)-3, in differentiating between early glaucomatous and healthy normal Chinese eyes. METHOD 52 healthy volunteers and 25 glaucoma patients were recruited for this prospective cross-sectional study. All underwent standardized interviews, ophthalmic examination, perimetry and HRT optic disc imaging. Area under the curve (AUC) receiver operating characteristics, sensitivity and specificity were derived to assess the discriminating abilities of the 3 normative databases, for both Moorfields Regression Analysis (MRA) and Glaucoma Probability Score (GPS). RESULTS A significantly higher percentage (65%) of patients were classified as "within normal limits" using the MRA-Indian database, as compared to the MRA-Caucasian and MRA-African-American databases. However, for GPS, this was observed using the African-American database. For MRA, the highest sensitivity was obtained with both Caucasian and African-American databases (68%), while the highest specificity was from the Indian database (94%). The AUC for discrimination between glaucomatous and normal eyes by MRA-Caucasian, MRA-African-American and MRA-Indian databases were 0.77 (95% CI, 0.67-0.88), 0.79 (0.69-0.89) and 0.73 (0.63-0.84) respectively. For GPS, the highest sensitivity was obtained using either Caucasian or Indian databases (68%). The highest specificity was seen with the African-American database (98%). The AUC for GPS-Caucasian, GPS-African-American and GPS-Indian databases were 0.76 (95% CI, 0.66-0.87), 0.77 (0.67-0.87) and 0.76 (0.66-0.87) respectively. CONCLUSION Comparison of the 3 ethnic databases did not reveal significant differences to differentiate early glaucomatous from normal Chinese eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of glaucoma probability score and Moorfields regression analysis to discriminate glaucomatous and healthy eyes.

PURPOSE To compare sensitivity and specificity values of glaucoma probability score (GPS) and Moorfields regression analysis (MRA) of Heidelberg retina tomograph (HRT) to discriminate between glaucomatous and healthy eyes. METHODS A total of 160 eyes of 160 individuals (80 glaucoma patients and 80 healthy subjects) were enrolled in this prospective cross-sectional study. Confocal scanning las...

متن کامل

Diagnostic ability of macular ganglion cell–inner plexiform layer thickness in glaucoma suspects

The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), an...

متن کامل

[Ability of Heidelberg Retina Tomograph III to predict progression in patients with early glaucoma or suspected primary open-angle glaucoma].

PURPOSE To study the ability of Heidelberg Retina Tomography III (HRT 3) measurements to predict perimetry changes in patients with early glaucoma or suspected primary open-angle glaucoma. MATERIAL AND METHODS One hundred and thirty two eyes with early glaucoma or suspected glaucoma with no changes in basal perimetry were prospectively selected and periodically evaluated over five years. The ...

متن کامل

Heidelberg Retina Tomography II parameters in evaluating high- and normal-pressure glaucoma progression.

BACKGROUND/AIM Heidelberg retina tomography II (HRT II) haves been employed to quantitatively assess the topography of optic discs in eyes with high-pressure glaucoma (HPG) and normal-pressure glaucoma (NPG), in order to determine which of global and segmental optic disc parameters will prove to be most suitable for monitoring the progression of these two conditions. METHODS The results of 73...

متن کامل

Detecting the Progression of Normal Tension Glaucoma: A Comparison of Perimetry, Optic Coherence Tomography, and Heidelberg Retinal Tomography

PURPOSE We compared the abilities of Stratus optical coherence tomography (OCT), Heidelberg retinal tomography (HRT) and standard automated perimetry (SAP) to detect the progression of normal tension glaucoma (NTG) in patients whose eyes displayed localized retinal nerve fiber layer (RNFL) defect enlargements. METHODS One hundred four NTG patients were selected who met the selection criteria:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017