Evaluation of an enhanced luminescence assay for alpha-fetoprotein.
نویسندگان
چکیده
We evaluated a two-site enhanced luminescence immunoenzymometric assay (Amerlite; Amersham International) for alpha-fetoprotein (AFP) in maternal serum and amniotic fluid. The assay is rapid, involving two incubations totalling 4 h. The working range of the assay for serum AFP is 5.5 to 750 kilo-int. units/L (CV less than 10%), with a sensitivity of detection of 0.2 kilo-int. unit/L. The regression equation for the Amerlite assay (y) and our in-house RIA procedure (x) was y = 0.816x + 2.9 (n = 142, r = 0.96). Analytical recovery of added AFP (code 72/227) at three concentrations was 86.7%. Serum AFP concentrations were measured at 15 to 18 weeks of gestation in subjects with normal pregnancies and in subjects whose pregnancies resulted in open neural tube defects; all of the latter had serum AFP concentrations greater than 2.5 multiples of the median. We find the Amerlite system to be an efficient, reliable system for screening for open neural tube defects without use of hazardous radioactive labels.
منابع مشابه
Silencing Alpha-Fetoprotein Inhibits VEGF and MMP-2/9 Production in Human Hepatocellular Carcinoma Cell
Alpha-fetoprotein not only serves as a diagnostic marker for liver cancer, but also posses a variety of biological functions. However, the role of Alpha-fetoprotein on tumor angiogenesis and cell invasion remains incompletely understood. In this study, we aimed to evaluate if Alpha-fetoprotein can regulate the major angiogenic factors and matrix metalloproteinases in human liver cancer cells. A...
متن کاملEvaluation of serum AFP (α-fetoprotein) level in HBsAg carrier patients for diagnosis of hepatocellular carcinoma
Background: Hepatocellular carcinoma (HCC) is common all over the world as well as Iran. The incidence of HCC is higher in hepatitis B carriers and it is highly recommended to periodically screen these patients by serum alpha-fetoprotein (AFP) and liver ultrasound (US) every 6 months. We explore the diagnostic accuracy and the performance of (AFP) in cases of hepatitis B carriers as a scree...
متن کاملIn vitro effect of dipyrone on several peroxidase labelled immunoassays.
We studied the in vitro effect of dipyrone on the determination of free triiodothyronine (free T3), cortisol, progesterone, estradiol, carcinoembryonic antigen, human chorionic gonadotropin and alpha-fetoprotein measured with an immunoenzyme assay based on enhanced luminescence that uses peroxidase as label. We found significant interference from dipyrone (p < 0.01) in the determination of all ...
متن کاملTumor Marker Detection: Ultrasensitive Luminescent In Vitro Detection for Tumor Markers Based on Inorganic Lanthanide Nano‐Bioprobes (Adv. Sci. 11/2016)
In article 1600197, Xueyuan Chen and co-workers report a novel luminescent bioassay technique, namely, dissolution-enhanced luminescence bioassay based on inorganic lanthanide nanoprobes, for ultrasensitive in-vitro detection of tumor markers in human sera or saliva, such as carcinoembryonic antigen, prostate specific antigen and alpha-fetoprotein, with detection sensitivities several orders of...
متن کاملInfluence of assay method differences on multiple of the median distributions: maternal serum alpha-fetoprotein as an example.
A straightforward statistical explanation is provided to show how differences between assay methods can affect the distribution of the multiples of the median (MoM). Evaluation of the impact of assay method differences reveals that the upper tails of the MoM distribution are not affected to the same degree as the lower tails of the distribution. The disparities in MoM distributions due to assay...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 32 11 شماره
صفحات -
تاریخ انتشار 1986