Bone Quality Assessment of Dental Implant Recipient Sites
نویسنده
چکیده
Th e term bone quality is not clearly defi ned and depends on many factors, such as bone density, bone vascularity, bone metabolism and other factors that may aff ect implant outcome. Th e assessment of bone volume and bone density is most common in planning the treatment of dental implants. Bone quality is an important predictor of primary implant stability, which infl uences the future implant osseointegration. Numerous classifi cations have been described for the evaluation of bone density. Th e most commonly used has been the one proposed by Lekholmu and Zarb. For the objective evaluation of bone density, conventional computed tomography (CT) or Cone Beam Computed tomography (CBCT), have been proposed. Both methods are reliable for the measurement of bone density, but preference is given to CBCT, due to the lower radiation doses, greater comfort for the patient and the lower prices. Pre-operatively defi ned bone density is a good indicator of the future success of implant therapy. In addition to the bone density, vascularity of the jawbone is an important factor of the quality of the bone for the osseointegration of dental implants. Laser Doppler is a simple method that can determine the vascularity of bone during implant insertion. Th e development of modern diagnostic methods for assessing the quantity and quality of the jawbone has enabled easier implant planning and has provided a secure outcome.
منابع مشابه
A Two-step Method for the Preparation of Implant Recipient Site in Severe Atrophic Maxilla: A Case Report of the Alveolar Ridge Split Technique Followed by Bone Expansion
Augmentation of deficient and atrophic alveolar ridges is an important aspect of dental implant therapy with the goal of providing a functional restoration in harmony with adjacent natural dentition. Bone splitting technique is considered a distinguished augmentation method for treatment of deficient alveolar ridges. According to this procedure, the compromised alveolar ridge is opened from the...
متن کاملبررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی
Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...
متن کاملResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملCorrelation of Fractal Dimension Values with Implant Insertion Torque and Resonance Frequency Values at Implant Recipient Sites.
PURPOSE Fractal analysis is a mathematical method used to describe the internal architecture of complex structures such as trabecular bone. Fractal analysis of panoramic radiographs of implant recipient sites could help to predict the quality of the bone prior to implant placement. This study investigated the correlations between the fractal dimension values obtained from panoramic radiographs ...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کامل