New wide-area algorithms for detecting angle instability using synchrophasors

نویسنده

  • Dongchen Hu
چکیده

Electric power system is undergoing major technological advances with many new installations of synchrophasors across the North American grid as well in power systems all over the world. Wide-area monitoring system (WAMS) in the Pacific Northwest and the Eastern Interconnection Phasor Project (EIPP) in the eastern grid are examples of such installations. Synchrophasors together with modern communication technology facilitate the monitoring of the current state of the power system including the phase angles of the bus voltages at critical buses in a time-synchronized fashion. Power system operation is constantly facing contingencies such as from line faults and generator outages. For operational reliability, the system must be able to withstand all credible contingencies, either by itself (for N-1 contingency) or with the help of Special Protection Schemes (SPS) or Remedial Action Schemes (RAS) (for N-2 or worse contingencies). However, when the system is operating under unforeseen conditions or under unusually high stress, the system can experience the angle instability. In that case, the system breaks up into many islands, resulting in large loss of loads and generations and a potential blackout scenario. In this paper, new algorithms are proposed for detecting the emergence of angle instability phenomenon while it is still evolving so that suitable countermeasures can be initiated to prevent the islanding. The proposed algorithms and the controller detect the fast separation of phase angles among the critical areas automatically by using the synchrophasors, and proceed to mitigate the instability by suitable switching action. Briefly, the algorithms initiate tripping of critical generators in the accelerating part of the system when necessary, and also initiate load shedding in the decelerating part of the system whenever necessary. The novelty of the algorithms is in the fact that all the decisions are made in real-time purely based on the wide-area synchrophasor measurements without any knowledge of the details of the relay actions that may have resulted in the angle stability phenomenon. The concept of a real-time transient energy function method for the large power system is also explored to solve the problem. The paper will discuss the new algorithms along with illustrative examples on standard IEEE test systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power System Observability and Dynamic State Estimation for Stability Monitoring Using Synchrophasor Measurements

Growing penetration of intermittent resources such as renewable generations increases the risk of instability in a power grid. This paper introduces the concept of observability and its computational algorithms for a power grid monitored by the wide-area measurement system (WAMS) based on synchrophasors, e.g. phasor measurement units (PMUs). The goal is to estimate real-time states of generator...

متن کامل

Croatian Academic Research Wide Area Monitoring System - CARWAMS

Paper describes start-up of Croatian Academic Research Wide Area Monitoring System (CARWAMS), which is intended to support involvement of small R&D teams into fast developing synchronized measurement technology (SMT). Low voltage synchrophasors are collected by platform called WAMSTER, including handheld Phasor Measurement Units (PMUs) and GPRS data transfer to a dedicated served. Measurements ...

متن کامل

Observability and Estimation Methods Using Synchrophasor

Intermittent generations such as large-scale renewable energy increases the risk of instability in a power grid. In this paper, we introduce the concept of observability and its computational algorithms for power networks equipped with synchrophasors. The goal is to estimate the angles and its derivatives around unstable trajectories, the information that is critical for the detection of power ...

متن کامل

Neuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements

In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...

متن کامل

Real-Time Synchrophasor Applications for Wide-Area Protection, Control, and Monitoring

To date, synchronized phasor measurements have been used mainly for power system model validation, post-event analysis, real-time display, and other similar activities. However, synchrophasors have a greater potential than monitoring and visualization. Synchrophasors will increasingly contribute to the reliable and economical operation of power systems as real-time control and protection scheme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006