A framework for continuous target tracking during MR-guided high intensity focused ultrasound thermal ablations in the abdomen

نویسندگان

  • Cornel Zachiu
  • Baudouin Denis de Senneville
  • Ivan D Dmitriev
  • Chrit T W Moonen
  • Mario Ries
چکیده

BACKGROUND During lengthy magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU) thermal ablations in abdominal organs, the therapeutic work-flow is frequently hampered by various types of physiological motion occurring at different time-scales. If left un-addressed this can lead to an incomplete therapy and/or to tissue damage of organs-at-risk. While previous studies focus on correction schemes for displacements occurring at a particular time-scale within the work-flow of an MRg-HIFU therapy, in the current work we propose a motion correction strategy encompassing the entire work-flow. METHODS The proposed motion compensation framework consists of several linked components, each being adapted to motion occurring at a particular time-scale. While respiration was addressed through a fast correction scheme, long term organ drifts were compensated using a strategy operating on time-scales of several minutes. The framework relies on a periodic examination of the treated area via MR scans which are then registered to a reference scan acquired at the beginning of the therapy. The resulting displacements were used for both on-the-fly re-optimization of the interventional plan and to ensure the spatial fidelity between the different steps of the therapeutic work-flow. The approach was validated in three complementary studies: an experiment conducted on a phantom undergoing a known motion pattern, a study performed on the abdomen of 10 healthy volunteers and during 3 in-vivo MRg-HIFU ablations on porcine liver. RESULTS Results have shown that, during lengthy MRg-HIFU thermal therapies, the human liver and kidney can manifest displacements that exceed acceptable therapeutic margins. Also, it was demonstrated that the proposed framework is capable of providing motion estimates with sub-voxel precision and accuracy. Finally, the 3 successful animal studies demonstrate the compatibility of the proposed approach with the work-flow of an MRg-HIFU intervention under clinical conditions. CONCLUSIONS In the current study we proposed an image-based motion compensation framework dedicated to MRg-HIFU thermal ablations in the abdomen, providing the possibility to re-optimize the therapy plan on-the-fly with the patient on the interventional table. Moreover, we have demonstrated that even under clinical conditions, the proposed approach is fully capable of continuously ensuring the spatial fidelity between the different phases of the therapeutic work-flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of volumetric MR-guided high-intensity focused ulatrsound ablations in moving organs

Introduction In this work, a method for the optimization of volumetric MR-guided high intensity focused ultrasound (HIFU) ablations is presented. While commonly MRguidance of thermal therapies is based on temperature control the on-line assessment of the thermal dose has been suggested to determine the therapy endpoint [1]. Therefore, we propose to monitor the thermal dose [2] of the treated ti...

متن کامل

High-intensity focused ultrasound for noninvasive functional neurosurgery.

Transcranial magnetic resonance (MR)-guided high-intensity focused ultrasound (tcMRgHIFU) implies a novel, noninvasive treatment strategy for various brain diseases. Nine patients with chronic neuropathic pain were treated with selective medial thalamotomies. Precisely located thermal ablations of 4mm in diameter were produced at peak temperatures of 51 degrees C to 60 degrees C under continuou...

متن کامل

Three dimensional motion compensation for real-time MRI guided focused ultrasound treatment of abdominal organs

Purpose/Introduction MR-guided High Intensity Focused Ultrasound (HIFU) for the ablation of tumors in abdominal organs under freebreathing conditions poses two challenges: 1) The current organ position in 3D-space must be continuously tracked in order to reposition the focal point of the HIFU-device to avoid undesired tissue damage. 2) Phase variations due to the organ displacement must be corr...

متن کامل

A Reliable Real Time Liver Motion Tracking for Application in Magnetic Resonance guided High Intensity Focused Ultrasound Therapy

Introduction High-intensity focused ultrasound has shown potential for ablating liver tumors without the need for surgical procedures [1]. However, the long duration of HIFU scans (~2hrs) and the varying respiratory motion requires that features identified for sonication be tracked in real time during the procedure [2]. The real time tracking would enable a free-breathing MRgFUS treatment and t...

متن کامل

Ablation of the sacroiliac joint using MR-guided high intensity focused ultrasound: a preliminary experiment in a swine model

BACKGROUND Dysfunction of the Sacroiliac Joint (SIJ) is one of the key sources of low back pain. For prolonged pain relief, some patients undergo fluoroscopic guided radio-frequency (RF) ablation of SIJ, during which a number of RF probes are inserted to create thermal lesions that disrupt the posterior sacral nerve supply. This procedure is minimally invasive, laborious, time-consuming and cos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017