Field-based evaluation of a reagent strip test for diagnosis of schistosomiasis mansoni by detecting circulating cathodic antigen (CCA) in urine in low endemic area in Ethiopia.
نویسندگان
چکیده
The sensitivity, specificity, positive and negative predictive values of a reagent strip test for the diagnosis of schistosomiasis mansoni by detecting circulating cathodic antigen (CCA) in urine were evaluated using 184 stool and urine samples collected from schoolchildren living in relatively low endemic area of schistosomiasis mansoni in Ethiopia. A combined result of stool samples processed by Kato and formol-ether concentration methods was used as gold standard. The results showed that detection of CCA in urine using reagent strip test was slightly higher than the combined results of the stool techniques (65.2 % vs 42.4 %, p > 0.05) in suggesting the prevalence of the disease. The sensitivity, specificity, positive and negative predictive values of the reagent strip test were 76.9 %, 43.4 %, 50 % and 71.9 %, respectively. The result of egg counts using Kato method suggested that detection of urine CCA could be used to indicate the intensity of infection. Nevertheless, like that of stool examination, the reagent strip test was found to be less sensitive in case of light to moderate infections. About 23.1 % of the study children who were excreting the eggs of the parasite were found negative by the reagent strip test. The relative insensitivity of a reagent strip test in low intensity of infection necessitates for the development of more sensitive assay that can truly discriminate schistosome-infected from non-infected individuals.
منابع مشابه
Field-based evaluation of a reagent strip test for diagnosis of Schistosoma mansoni by detecting circulating cathodic antigen in urine before and after chemotherapy.
The sensitivity of a reagent strip test for the diagnosis of schistosomiasis by detecting circulating cathodic antigen (CCA) in urine was evaluated under field conditions using 251 stool and urine samples collected from a Schistosoma mansoni-endemic area of Ethiopia. The specificity of the test was evaluated in an area where schistosomiasis is not endemic. Stool samples were examined microscopi...
متن کاملEvaluation of circulating cathodic antigen (CCA) strip for diagnosis of urinary schistosomiasis in Hassoba school children, Afar, Ethiopia.
A total of 206 urine samples collected from Hassoba Elementary schoolchildren, Afar, Ethiopia, a low Schistosoma haematobium endemic setting, was diagnosed to evaluate the performance of CCA strip using double references, urine filtration technique and urinalysis dipstick (Combur 1.0 Test) that detect schistosome eggs and blood in urine, respectively. The former was used as a gold standard refe...
متن کاملValidation of a Point-of-Care Circulating Cathodic Antigen Urine Cassette Test for Schistosoma mansoni Diagnosis in the Sahel, and Potential Cross-Reaction in Pregnancy.
On the shores of Lake Chad, schistosomiasis among mobile pastoralists was investigated in a field laboratory. Point-of-care circulating cathodic antigen (POC-CCA) cassette test, reagent strip, and filtration were conducted on urine samples. Fresh stool samples were subjected to the Kato-Katz technique, and fixed samples were examined with an ether-concentration method at a reference laboratory....
متن کاملDiagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen.
A newly developed reagent strip assay for the diagnosis of schistosomiasis based on parasite antigen detection in urine of infected individuals was evaluated. The test uses the principle of lateral flow through a nitrocellulose strip of the sample mixed with a colloidal carbon conjugate of a monoclonal antibody specific for Schistosoma circulating cathodic antigen (CCA). The strip assay to diag...
متن کاملRapid diagnosis of schistosomiasis by antigen detection in urine with a reagent strip.
For the rapid and simple diagnosis of schistosomiasis, a reagent strip assay for detection of circulating cathodic antigen (CCA) in urine was developed. The test was based on a previously developed sandwich enzyme-linked immunosorbent assay (ELISA) using a combination of two anti-CCA monoclonal antibodies. For the reagent strip assay, as the capture matrix, monoclonal antibody was coated onto a...