Assessment of rapid E.S.R. estimaton using an inclined tube.
نویسنده
چکیده
IT IS WELL-KNOWN that failure to keep an E.S.R. tube vertical will result in a falsely high reading. An inclination of as little as 5° will cause sedimentation to take place more rapidly. Inclining the tube reduces the vertical distance of fall and increases the horizontal area of cross-section by the reciprocal of that factor. The Martin E.S.R. kit consists of a tube of the same bore as the standard Westegren tube. It is supplied with a wooden case which serves two functions: (1) To act as a carrier for the tube. (2) To act as a holder so that the tube may be held either vertically or at 30°. The makers claim that when the tube is held in the latter position a 7 minute reading will correspond to a one-hour reading on a standard vertical tube. It should be added that the reading must be taken from the side (i.e. in profile) and not from the front (i.e. 'en face') because the thin red line of R.B.C.'s which collect on the dependent surface of the tube make it impossible to get a correct reading from a front view. An accurate 7 minute E.S.R. estimation would be of tremendous value in general practice and in busy casualty departments. Unfortunately the first 15 controlled tests carried out with the sloping tube indicated that the makers' claims of accuracy for this period were quite untenable (See table: tests 1-15). Results number 1 and 10 show that even a very elevated E.S.R. could be overlooked if a 7 minute reading were relied upon. The search for an accurate E.S.R. estimation using an inclined tube was hence abandoned, but further tests were carried out to ascertain whether a rapid screening test which would serve an alerting function in indicating a significantly raised E.S.R. could be devised using this apparatus. A total of fifty controlled tests were carried out against the standard vertical Westegren pipette (See table test 1-50). A number of preliminary trials (not recorded here) had seemed to indicate that a 12 minute reading on the inclined tube might be the most useful for this purpose. It was arbitrarily decided to regard as 'significantly raised' readings of 15 mms. per hour and over with respect to the vertical tube and 30 mms. and over with respect to the 12 minute reading on the inclined tube. RESULTS Applying the criteria of significance given above, it was found: (i) In 36 out of 50 comparative tests (72 per cent) there was agreement between the results from the standard Westegren 1-hour readings and the sloping (30° horizontal) 12 minute Martin readings. (ii) In 10 out of 50 comparative tests the screening test was too sensitive, i.e., there were 20 per cent of false positives given by the Martin apparatus (See tests numbers 3, 7, 15, 23, 25, 28, 32, 34, 41 and 42).
منابع مشابه
Creep Life Assessment of Primary Reformer HP40-NB Modified Steel Tube of an Ammonia Plant
Assessment of creep damage and residual creep life of a cast HP 40 Nb Mod. Reformer tube was performed, wherein the experimental Larson–Miller diagram and area fraction of creep voids were adopted. The state of damage of the tube in service was metallographically analyzed by using light and electron microscopy. Samples from the serviced reformer furnace tube were cut and prepared for void exami...
متن کاملConvective Heat Transfer of Oil Based Nanofluid Flow Inside a Circular Tube
Abstract An empirical investigation was carried out to study convective heat transfer of nanofluid flow inside an inclined copper tube under uniform heat flux condition. Required data are acquired for laminar and hydrodynamically fully developed flow inside round tube. The stable CuO-base oil nanofluid with different nanoparticle weight fractions of 0.5%, 1% and 2% was produced by means of ul...
متن کاملIndustrial waste management using the rapid impact assessment matrix method for an industrial park
Due to the growth of population and industrialization, a great number of problems associated with producing industrial wastes have been created for both the environment and human beings. The industrial waste management in Brujen industrial park, located in the western part of Iran, has been investigated in this study using the environmental rapid impact assessment matrix techn...
متن کاملTheoretical Study of Indirect Heating Temperature Swing Adsorption in an Adsorbent Coated Finned Tube Heat Exchanger
In this study, the performance of an adsorbent coated finned tube exchanger for carbon capture was investigated numerically. The results showed that this structure has a great potential for being applied as a medium for CO2 capture by rapid indirect thermal swing adsorption. By using this structure, the recovery of 96%, and purity of 98% were achieved with a simple cycle consisting of two steps...
متن کاملEFFECT OF THE INCLINED COOLING PLATE CHARACTERISTICS ON THE THIXOTROPIC MICROSTRUCTURE OF A356.0 ALUMINUM ALLOY
In the present work microstructural evolution of A356 Aluminum alloy using an inclined cooling plate casting process for thixoforming feedstock production is investigated. The resultant microstructure was evaluated and compared with those of the same alloy produced by the conventional casting process, i.e. directly cast in the same mold without using an inclined cooling plate. It was found that...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Ulster Medical Journal
دوره 39 شماره
صفحات -
تاریخ انتشار 1970