The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband

نویسندگان

  • Friedrich Ihler
  • Jenny Blum
  • Max-Ulrich Berger
  • Bernhard G. Weiss
  • Christian Welz
  • Martin Canis
چکیده

Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneous bone conduction device to external stimulation with a bone conduction device fixed by a headband. Eight German-language adult patients were enrolled after a semi-implantable transcutaneous bone conduction device (Bonebridge, Med-El) was implanted and fitted. Patients received a bone conduction device for external stimulation (Baha BP110, Cochlear) fixed by a headband for comparison. The main outcome measure was speech recognition in noise (Oldenburg Sentence Test). Pure-tone audiometry was performed and subjective benefit was assessed using the Glasgow Benefit Inventory and Abbreviated Profile of Hearing Aid Benefit questionnaires. Unaided, patients showed a mean signal-to-noise ratio threshold of 4.6 ± 4.2 dB S/N for speech recognition. The aided results were -3.3 ± 7.2 dB S/N by external bone conduction stimulation and -1.2 ± 4.0 dB S/N by the semi-implantable bone conduction device. The difference between the two devices was not statistically significant, while the difference was significant between unaided and aided situation for both devices. Both questionnaires for subjective benefit favored the semi-implantable device over external stimulation. We conclude that it is possible to simulate the result of speech recognition in noise with a semi-implantable transcutaneous bone conduction device by external stimulation. This should be part of preoperative counseling of patients with CHL/MHL before implantation of a bone conduction device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of sensorineural hearing loss and tinnitus on speech recognition over air and bone conduction military communications headsets

Military personnel are at risk for hearing loss due to noise exposure during deployment (USACHPPM, 2008). Despite mandated use of hearing protection, hearing loss and tinnitus are prevalent due to reluctance to use hearing protection. Bone conduction headsets can offer good speech intelligibility for normal hearing (NH) listeners while allowing the ears to remain open in quiet environments and ...

متن کامل

Active Bone Conduction Prosthesis: BonebridgeTM

Introduction Bone conduction implants are indicated for patients with conductive and mixed hearing loss, as well as for patients with single-sided deafness (SSD). The transcutaneous technology avoids several complications of the percutaneous bone conduction implants including skin reaction, skin growth over the abutment, and wound infection. The Bonebridge (MED-EL, Austria) prosthesis is a semi...

متن کامل

A Bone Conduction Implantable Device as a Functional Treatment Option in Unilateral Microtia with Bilateral Stapes Ankylosis: A Report of Two Cases

BACKGROUND Implantable devices have been proposed as an alternative to hearing aids and auditory canal reconstruction in patients with microtia (congenital aural atresia), which includes a malformation of the external and middle ear. This report is of two rare cases of microtia associated with congenital stapes ankylosis treated with an implantable device and describes the treatment outcomes. C...

متن کامل

تغییرات هدایت استخوانی پس از بازسازی زنجیره استخوانچه‌ای گوش میانی

    Background & Aim: The most common surgically treatable causes of hearing loss are middle ear diseases among which the greatest effect is related to ossicular chain dysfunction. Successful ossicular chain reconstruction certainly improves air conduction thresholds and closes air-bone gap in audiograms, but the effect of this procedure on bone conduction thresholds has remained to be elucidat...

متن کامل

Sensory neural hearing loss following Tympanomastoid surgery

Objective: Generated acoustic trauma by suction and drill may cause sensorineural hearing loss after Tympanomastoid surgery. This study was carried out to determine the relationship of sensorineural hearing loss and chronic otitis media surgery at Ahvaz Jundishapur University of Medical Sciences in Iran. Material and Methods: This prospective study included 386 patients of ch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016