MOX–Report No. 43/2011 On the physical consistency of the coupling between three-dimensional compliant and one-dimensional problems in haemodynamics

نویسندگان

  • L. Formaggia
  • A. Quarteroni
  • C. Vergara
  • Luca Formaggia
  • Alfio Quarteroni
  • Christian Vergara
چکیده

In this work we discuss the reliability of the coupling among three-dimensional (3D) and one-dimensional (1D) models, that describe blood flowing into the circulatory tree. In particular, we study the physical consistency of the 1D model with respect to the 3D one. To this aim, we introduce a general criterion based on energy balance for the proper choice of coupling conditions between models. We also propose a way to include in the 1D model the effect of the external tissue surrounding the vessel and we discuss its importance whenever this effect is considered in the 3D model. Finally, we propose several numerical results in real human carotids, studying different configurations for the 1D model and highlighting the best one in view of the physical consistency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting three-dimensional displacement around the tunnel and its impact on the value of Q-system

Having knowledge of stability of an underground space depends on stresses and strains around it. Creating underground tunnels leads to significant changes in the rock mass stress. Therefore, to achieve the necessary stability, stresses and deformations around the tunnel must be examined carefully. Usually, stress-strain behavior analysis is conducted in two-dimensional mode. This paper was cond...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Two Dimensional Mathematical Model of Tumor Angiogenesis: Coupling of Avascular Growth and Vascularization

Introduction As a tumor grows, the demand for oxygen and nutrients increases and it grows further if acquires the ability to induce angiogenesis. In this study, we aimed to present a two-dimensional continuous mathematical model for avascular tumor growth, coupled with a discrete model of angiogenesis. Materials and Methods In the avascular growth model, tumor is considered as a single mass, wh...

متن کامل

تحلیل سه‌بعدی اکستروژن مستقیم با روش قاچی و المان محدود

Slab method of analysis has been used for solving metal forming problems for a long time. However it has been restricted to plane strain and axisymmetric problems due to limitations in its formulations. In this paper a new formulation has been proposed so that it could be applied to three dimensional problems in metal forming. A parametric slab has been considered in this analysis and the force...

متن کامل

ON MAXWELL'S STRESS FUNCTIONS FOR SOLVING THREE DIMENSIONAL ELASTICITY PROBLEMS IN THE THEORY OF ELASTICITY

The governing equations of three dimensional elasticity problems include the six Beltrami-Michell stress compatibility equations, the three differential equations of equilibrium, and the six material constitutive relations; and these are usually solved subject to the boundary conditions. The system of fifteen differential equations is usually difficult to solve, and simplified methods are usual...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011