  • Fumiyuki Otsuka
  • Masataka Nakano
  • Elena Ladich
  • Frank D. Kolodgie
  • Renu Virmani
چکیده

Several randomized and observational studies have reported steady increase in cumulative incidence of late and very late ST (LST/VLST) following first-generation drug-eluting stents (DES: sirolimus-(SES) and paclitaxel-(PES)) up to 5 years. Pathologic studies have identified uncovered struts as the primary substrate responsible for LST/VLST following DES, where delayed arterial healing is associated with stent struts penetrating into the necrotic core, long/overlapping stents, and bifurcation stenting especially in flow divider region. Grade V stent fracture also induces LST/VLST and restenosis. Hypersensitivity reaction is exclusive to SES as an etiology of LST/VLST, whereas malapposition secondary to excessive fibrin deposition is associated with PES. Uncovered struts can be identified in SES and PES with duration of implant beyond 12 months, particularly in stents placed for "off-label" indications. Neoatherosclerosis is another important contributing factor for VLST in DES and bare metal stents (BMS); however, DES shows rapid and more frequent development of neoatherosclerosis than BMS. Future pathologic studies should address the long-term safety of newer generation DES including zotarolimus- and everolimus-eluting stents in terms of the improvement in reendothelialization, decreased inflammation and fibrin deposition as well as a lower incidence of stent fracture-related adverse events, and reduced neoatherosclerosis, which likely contribute to the decreased risk of LST/VLST and better patient outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incredibly late thromboses in first generation drug eluting stents: a case series

BACKGROUND The drug-eluting stents have decreased the incidence of instent restenosis compared to bare metal stents. But, the incidence of late and very late stent thrombosis has increased with the drug-eluting stents. CASE PRESENTATION We are here, reporting three cases of incredibly late instent thrombosis, each one occurring after more than 50 months of drug-eluting stent placement. CONC...

متن کامل

Late and Very Late Stent Thrombosis in the Era of Second-generation Drug-eluting Stents

Stent thrombosis is a life-threatening complication of percutaneous coronary intervention that often results in ST-segment myocardial infarction or sudden cardiac death. First-generation drug-eluting stents (DESs) are associated with an increased risk of late and very late stent thrombosis compared with baremetal stents due to delayed endothelialisation of the stent struts. The second-generatio...

متن کامل

Triple, simultaneous, very late coronary stent thrombosis.

Coronary artery stent thrombosis is an uncommon but potentially catastrophic complication. The risk of very late stent thrombosis (VLST) raises important safety issues regarding the first generation of drug-eluting stents (DES). Although several complex mechanisms for VLST have been suggested and various predictors have been described, its pathophysiology is not completely understood and it is ...

متن کامل

Neoatherosclerosis: overview of histopathologic findings and implications for intravascular imaging assessment.

Despite the reduction in late thrombotic events with newer-generation drug-eluting stents (DES), late stent failure remains a concern following stent placement. In-stent neoatherosclerosis has emerged as an important contributing factor to late vascular complications including very late stent thrombosis and late in-stent restenosis. Histologically, neoatherosclerosis is characterized by accumul...

متن کامل

Novel stent and drug elution technologies

To address concerns of late and very late stent thrombosis associated with first generation drug-eluting stent technology, novel approaches are being tested including stents with bioabsorbable polymers (including Biomatrix FlexTM, NoboriTM and SynergyTM), polymer-free drug delivery systems (including BiofreedomTM and Yukon®) and drug-eluting balloons (including Sequent PleaseTM, Dior® II and Pa...