Development of a variable-radius pinhole SPECT system with a portable gamma camera.

نویسندگان

  • F Pino
  • N Roé
  • A Orero
  • C Falcón
  • S Rojas
  • J M Benlloch
  • D Ros
  • J Pavía
چکیده

OBJECTIVE To develop a small-animal SPECT system using a low cost commercial portable gamma camera equipped with a pinhole collimator, a continuous scintillation crystal and a position-sensitive photomultiplier tube. MATERIAL AND METHODS The gamma camera was attached to a variable radius system, which enabled us to optimize sensitivity and resolution by adjusting the radius of rotation to the size of the object. To investigate the capability of the SPECT system for small animal imaging, the dependence of resolution and calibration parameters on radius was assessed and acquisitions of small phantoms and mice were carried out. RESULTS Resolution values, ranging from 1.0mm for a radius of 21.4mm and 1.4mm for a radius of 37.2mm were obtained, thereby justifying the interest of a variable radius SPECT system. CONCLUSIONS The image quality of phantoms and animals were satisfactory, thus confirming the usefulness of the system for small animal SPECT imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging.

OBJECTIVES Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera ...

متن کامل

Evaluation of high-resolution pinhole SPECT using a small rotating animal.

UNLABELLED Ex vivo measurements in animals are used frequently in the field of nuclear medicine for the characterization of newly developed radioligands and for drug development. In vivo SPECT would replace these ex vivo measurements in a relatively large number of cases if one were able to adequately image small organs. The pinhole collimator has been used extensively to obtain greater detail ...

متن کامل

Feasibility of portable gamma camera imaging in intraoperative radioguided parathyroid adenoma identification

Novel surgical applications include radioguided procedures in parathyroidectomy operations. In order to investigate the feasibility of usage of the portable gamma camera in parathyroidectomy operations; intraoperative radioguided parathyroidectomy operation was performed in three hyperparathyroidism patients with inconclusive preoperative parathyroid scintigraphy results. Intraoperative portabl...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

A pinhole gamma camera with optical depth-of-interaction elimination.

The performance of pinhole single photon emission computed tomography (SPECT) depends on the spatial resolution of the gamma-ray detectors used. Pinhole cameras suffer from strong resolution loss due to the varying depth-of-interaction (DOI) of gamma quanta that enter the detector material at an angle. We eliminate DOI effects in a scintillation gamma camera via a dedicated optic fiber bundle t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de medicina nuclear

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 2011