Permanent Parahisian Pacing

نویسندگان

  • Eraldo Occhetta
  • Miriam Bortnik
  • Paolo Marino
چکیده

Right Ventricular Apical permanent pacing could have negative hemodynamic effects. A physiologic pacing modality should preserve a correct atrio-ventricular and interventricular synchronization. This can be obtained through biventricular pacing, left ventricular pacing, or from alternative right ventricular pacing sites. Direct His Bundle Pacing (DHBP) was documented as reliable and effective for preventing the desynchronization and negative effects of right ventricular apical pacing. It is, however, a complex method that requires longer average implant times, cannot be carried out on all patients and presents high pacing thresholds. On the contrary, the parahisian pacing, with simpler feasibility and reliability criteria, seems to guarantee an early invasion of the His-Purkinje conduction system, with a physiological ventricular activation, very similar to the one that can be obtained with direct His bundle pacing. We present our experience on 68 patients who underwent a permanent right ventricular pacing in hisian/parahisian region, for advanced AV block and narrow QRS. In the first 17 patients we performed a double-blind randomized controlled study, with two 6-months cross-over periods in parahisian and apical pacing, documenting a significant improvement of NYHA class, exercise tolerance, quality of life score, mitral and tricuspidal regurgitation degree, and interventricular mechanical delay. In the subsequent 51 patients, in a mean follow of 21 months/patient, the pacing threshold remained stable (0.7+/-0.5 V implant; 0.9+/-0.7 V follow-up; p=0.08). The ejection fraction maintained medium-long term stable values, confirming the fact that the parahisian pacing can prevent deterioration of the left ventricular function. Parahisian pacing, therefore, has proven to be a reliable method, easy to apply and effective in preventing the negative effects induced by non-physiological right ventricular apical pacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyper-response to cardiac resynchronization with permanent His bundle pacing: Is parahisian pacing sufficient?

The feasibility of resynchronizing ventricular activation by permanent pacing of the His bundle region has been previously described, and has clinical advantages over traditional right ventricular (RV) apical pacing.1–4 The physiologic benefit of permanent His bundle pacing (HBP) is the ability to stimulate the ventricles through the intrinsic His-Purkinje system, which results in synchronous e...

متن کامل

Catheter inversion technique for ablation of parahisian accessory pathway.

A case of WPW Syndrome due to parahisian accessory pathway was ablated by the catheter inversion technique. The pathway could not be eliminated by direct femoral approach using repeated high radiofrequeny energy ablation. No pathway potential was seen in the aortic cusps. Instead, it was successfully ablated by curving the ablation catheter underneath the septal leaflet of the tricuspid valve t...

متن کامل

Parahisian Atrial Tachycardia: Cryoablation from the Aortic Cusp

A 29-year-old female patient with Ebstein anomaly was referred to our division for drugresistant symptomatic wide-complex tachycardia. Her preprocedural electrocardiograms showed a sinus rhythm without delta wave and a wide-complex short RP tachycardia with a rate of 150 bpm during palpitation. During conventional electrophysiologic study earliest local activation times during the tachycardia w...

متن کامل

Combination of Hansen Robotic system with cryocatheter in a challenging parahisian accessory pathway ablation

A perceived distinctive feature of cryoablation is the stability (cryoadherence) of the catheter tip during cold temperatures at the desired location, even during tachycardia. We report the case report of a young patient with a parahisian accessory pathway where stability of the ablation catheter was not achieved despite using the cryocatheter with a steerable sheath. Ultimately, stability at t...

متن کامل

Paradoxical Response During Para-hisian Pacing: What is the Mechanism?

A 64 year old lady underwent electrophysiologic study for recurrent episodes of palpitation and documented narrow complex tachycardia. 12 lead ECG showed normal sinus rhythm and no evidence of preexcitation. At baseline, the cycle length, AH and HV intervals were 776, 52 and 46 ms respectively. Para-Hisian pacing was done at baseline and the response is shown in figure 1. The pacing output duri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007