A Biomechanical Study Comparing Cerclage Wiring Performed with a Power Tool versus the Manual Method.

نویسندگان

  • Kevin Koo
  • Zhihong Zhou
  • Andy Ks Yew
  • Joyce Sb Koh
  • Tet Sen Howe
چکیده

INTRODUCTION We conducted a biomechanical study comparing cerclage wiring using a power tool with the traditional manual method. MATERIALS AND METHODS Our study consisted of 4 experimental arms based on the method of fixation and diameter of wires. The 4 arms were: 1) power tool method using 0.8 mm cerclage wires, 2) power tool method using 1.0 mm cerclage wires, 3) conventional manual method using 0.8 mm cerclage wires, and 4) conventional manual method using 1.0 mm cerclage wires. Synthetic femur bones were employed in our study. Six specimens were prepared for each arm. Each specimen was cut lengthwise and pressure sensors were placed in between. For the power tool method, while maintaining tension, wires were coiled using the Colibri power tool until just before secondary coiling occurred. For the conventional manual method, each specimen was compressed by plier twisting for 10 rounds, while maintaining tension. Cerclaging and data recording was done thrice for each specimen, giving a total of 18 readings per arm. Peak and steady-state forces were recorded. RESULTS There was no significant difference between the peak forces recorded between the power drill and manual methods. The steady-state forces achieved using the power tool method were significantly higher than that achieved in the manual fixation method (0.8 mm wires: 54.89N vs 27.26N, P = 0.037; 1.0 mm wires: 71.59N vs 39.66N, P = 0.025). CONCLUSION The power tool method achieved a superior steady-state force of compression across the fracture site for both 0.8 mm and 1 mm wires.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of cerclage wire for surgical repair of unilateral rostral mandibular fracture in horses

Fractures of the rostral mandible in horses are the most common type of jaw fractures. The present study was performed for stabilization of rostral mandibular fracture with cerclage wire. In a retrospective case series, six client-owned horses with unilateral mandibular fractures were admitted to our clinic and suffered from a major gingival wound at rostral part of mandible. Rostral mandibular...

متن کامل

Assessment of the adecuacy of KIM-LHC method in assessing the risk level based on biomechanical loads for manual lifting tasks: A laboratory study

Introduction: Manual Material handling includes activities in which pushing, pulling, lifting, lowering, carrying, and holding the load, the most common of which is lifting. This study aimed to evaluate the reliability of the KIM-LHC method to identify high-risk manual load lifting tasks. Material and Methods: This cross-sectional study was performed on healthy male workers with a history of m...

متن کامل

Separate Vertical Wiring for the Fixation of Comminuted Fractures of the Inferior Pole of the Patella

PURPOSE Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). MATERIALS AND METHODS Multiple oste...

متن کامل

Comparing the Accuracy of Waist-Hip Ratio Calculation by the BIA device versus the Manual Method

Nowadays, the Waist-Hip Ratio is considered one of the most important indices in predicting the risk of cardiovascular diseases. The usual method for calculating this index is by measuring the waist and hip circumferences with a measuring tape. However, bioelectrical impedance analysis (BIA) devices are also capable of calculating this ratio. Hence, the goal of this study was to calculate this ...

متن کامل

ELECTIVE VERSUS ULTRASOUND –INDICATED CERVICAL CERCLAGE IN WOMEN AT RISK FOR CERVICAL INCOMPETENCE

 ABSTRACT Background: To compare pregnancy outcomes in women at risk for cervical incompetence after elective versus ultrasound- indicated cerclage. Methods: In a prospective randomized tlial, singleton pregnancies with at least one previous spontaneous midtrimester loss or early preterm delivery (between 15 and 32 weeks' gestation) who met clinical crite1ia for the diagnosis of cervical incomp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 44 12  شماره 

صفحات  -

تاریخ انتشار 2015