An in vitro test bench reproducing coronary blood flow signals
نویسندگان
چکیده
BACKGROUND It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on in vivo measurements. METHODS An in vitro cardiovascular simulator is alimented with in vivo constraints upstream and provided with further post-processing analysis downstream in order to mimic the pulsatile in vivo blood flow quantities. This real-time controlled system is designed to perform real pulsatile in vivo blood flow signals to study endothelial cells' behavior under near physiological environment. The system is based on an internal model controller and a proportional-integral controller that controls a linear motor with customized piston pump, two proportional-integral controllers that control the mean flow rate and temperature of the medium. This configuration enables to mimic any resulting blood flow rate patterns between 40 and 700 ml/min. In order to feed the system with reliable periodic flow quantities in vivo measurements were performed. Data from five patients (1 female, 4 males; ages 44-63) were filtered and post-processed using the Newtonian Womersley's solution. These resulting flow signals were compared with 2D axisymmetric, numerical simulation using a Carreau non-Newtonian model to validate the approximation of a Newtonian behavior. RESULTS This in vitro test bench reproduces the measured flow rate time evolution and the complexity of in vivo hemodynamic signals within the accuracy of the relative error below 5%. CONCLUSIONS This post-processing method is compatible with any real complex in vivo signal and demonstrates the heterogeneity of pulsatile patterns in coronary arteries among of different patients. The comparison between analytical and numerical solution demonstrate the fair quality of the Newtonian Womersley's approximation. Therefore, Womersley's solution was used to calculate input flow rate for the in vitro test bench.
منابع مشابه
An in Vitro Cost-effective Test Bench for Active Cardiac Implants, Reproducing Human Exposure to Electric Fields 50 Hz
The European Directive 2013/35/UE sets the minimum requirements for the protection of workers exposed to electromagnetic fields and defines workers bearing implants as workers at particular risk. The European standards 50527-1 and 50527-2-1 propose risk assessments methods for these workers, including numerical and/or experimental in-vitro approaches. This study aims to conceive by using both m...
متن کاملDoppler ultrasound detection of side-vessel occlusion: an in vitro study.
BACKGROUND AND PURPOSE Small-vessel knock is a recently reported Doppler ultrasound finding that has been identified in patients with cerebral ischemia. It has been hypothesized that knock-type signals are linked to the presence of either small-vessel occlusion or wall motion. The aim of this study was to investigate the origins of "knock-type" signals by reproducing occlusion of a peripheral a...
متن کاملExperimental study of blood laminar flow through a stented artery
The objective of this research is to study the blood flow close to the wall of a stented artery. Indeed, previous works have showed that the restenosis phenomenon is induced by the endothelial cells stimulation due to the wall shear stress values. The coronary angioplasty is responsible of wall shear stress modification, mainly between the stent struts, at the inlet and the outlet of the endopr...
متن کاملAn advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملExtracorporeal CO2 removal by hemodialysis: in vitro model and feasibility
BACKGROUND Critically ill patients with acute respiratory distress syndrome and acute exacerbations of chronic obstructive pulmonary disease often develop hypercapnia and require mechanical ventilation. Extracorporeal carbon dioxide removal can manage hypercarbia by removing carbon dioxide directly from the bloodstream. Respiratory hemodialysis uses traditional hemodialysis to remove CO2 from t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2015