Passively-coupled, low-coherence interferometric duct profiling with an astigmatism-corrected conical mirror.
نویسندگان
چکیده
Duct-profiling in test samples up to 25 mm in diameter has been demonstrated using a passive, low-coherence probe head with a depth resolution of 7.8 μm, incorporating an optical-fibre-linked conical mirror addressed by a custom-built array of single-mode fibres. Zemax modelling, and experimental assessment of instrument performance, show that degradation of focus, resulting from astigmatism introduced by the conical mirror, is mitigated by the introduction of a novel lens element. This enables a good beam focus to be achieved at distances of tens of millimetres from the cone axis, not achievable when the cone is used alone. Incorporation of the additional lens element is shown to provide a four-fold improvement in lateral imaging resolution, when compared with reflection from the conical mirror alone.
منابع مشابه
Experimental Study of a Flash-lamp Pumped Passively Q-Switched Nd:YAG Laser Using Cr4+:YAG Saturable Absorber
This paper deals with the experimental results of a xenon flash-lamp pumped passively Q-switched Nd:YAG laser using Cr4+:YAG saturable absorber. The need of a laser cavity to be integrated into a time-of-flight laser range finder is of great interest as an experimental investigation of several laser resonators. Two types of laser resonator, with different lengths, have been studied: the flat-fl...
متن کاملA simple method for astigmatic compensation of folded resonator without Brewster window.
A folded resonator requires an oblique angle of incidence on the folded curved mirror, which introduces astigmatic distortions that limit the performance of the lasers. We present a simple method to compensate the astigmatism of folded resonator without Brewster windows for the first time to the best of our knowledge. Based on the theory of the propagation and transformation of Gaussian beams, ...
متن کاملIdentical twins with "mirror image" anisometropia and esotropia.
INTRODUCTION Identical twins account for 0.2% of the world population and 8% of all twins. A "mirror image" variation can be found in 25% of identical twins. Studies of twins assume a special place in human genetics due to the possibility of comparing genetic and other factors. We present two pairs of identical male twins with mirror-image astigmatism and esotropia. CASE OUTLINE The first was...
متن کاملMinimum amount of astigmatism that should be corrected.
PURPOSE To evaluate how small amounts of astigmatism affect visual acuity and the minimum astigmatism values that should be corrected to achieve maximum visual performance. SETTING Optics Laboratory, University of Murcia, Murcia, Spain. DESIGN Case series. METHODS A wavefront sensor was used to measure astigmatism and higher-order aberrations (HOAs) in normal young eyes with astigmatism r...
متن کاملDesign of the Advanced Virgo non-degenerate recycling cavities
Advanced Virgo is the project to upgrade the interferometric gravitational wave detector Virgo, and it foresees the implementation of power and signal non-degenerate recycling cavities. Such cavities suppress the build-up of high order modes of the resonating sidebands, with some advantage for the commissioning of the detector and the build-up of the gravitational signal. Here we present the ba...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 25 8 شماره
صفحات -
تاریخ انتشار 2017