A novel validated solution for lightning and surge protection of distribution transformers

نویسندگان

  • P. S. Georgilakis
  • A. G. Kagiannas
چکیده

This paper proposes an industrial solution (equipment) for lightning and surge protection of distribution transformers. The proposed protection equipment has been installed at 100 distribution transformers (sample) of the Public Power Corporation (PPC) of Greece. The article estimates the future transformer failures, considering two different cases: (a) transformer without the proposed protection system; and (b) transformer equipped with the proposed protection system. Three different methods are used to estimate the future transformer failures without the proposed protection system: Monte Carlo simulation, Poisson statistical distribution, and binomial statistical distribution. These three methods together with the c control chart method are also used in this paper, for the case of transformers equipped with the proposed protection system, to estimate the maximum allowable number of yearly transformer failures in order the proposed protection system to be considered as an effective protection means. Moreover, the article computes the satisfactory sample size of transformers in which the protection system has to be installed in order to be able to obtain statistically reliable results regarding the effectiveness of the proposed protection system. The results show that the proposed method is an excellent means for lightning and surge protection of distribution transformers, since zero transformer failures have been observed so far during the whole period of its operation (29 months), in contrast with 8.36 average lightning and surge related failures per year in the same sample of 100 transformers before the installation of the proposed protection equipment. 2014 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Performance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer

Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by l...

متن کامل

Zorc for Protection of Medium and Low Voltage Motors and Transformers

a unique high frequency transient overvoltage surge suppressor for the protection of motors and transformers from steep wave-front, short rise-time, high magnitude, spikes, surges and other transient voltages, generated by switching, lightning and other sources. The protective characteristics of ZORC: Eliminates inter-turn insulation failures Extends the life of machine insulation Eliminates mu...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...