Biomechanical Performance of Headless Compression Screws: Fixos Ø4.0, 5.0 & 7.0 mm compared to Synthes Ø4.5 & 6.5 mm HCS

نویسنده

  • M. Vallotton
چکیده

Introduction: The screw biomechanical performance plays a crucial role on the early interfragmentary stability and, in turn, on the fracture healing outcome. To assess the biomechanical performance of the headless compression screws Fixos 4.0, 5.0 & 7.0 mm, interfragmentry compression force and pull-out strength were determined and compared to the Synthes 4.5 & 6.5 mm HCS. Materials & Method: Interfragmentary compression force and pull-out strength were determined in a synthetic bone material. Results: The interfragmentary compression force generated by the Fixos screws was higher than the force of the Synthes HCS (by 47%, 75% and 72%, for group Ø4.0-4.5, Ø4.5-5.0 and Ø6.5-7.0 mm, respectively). In addition, the pull-out strength associated to Fixos screws was higher than the pull-out strength of the Synthes HCS by 27% and 9%, for group Ø4.5-5.0 and Ø6.5-7.0 mm, respectively. For group Ø4.0-4.5 mm, the pull-out strength of Fixos screw was 9% lower. Discussion and conclusion: These results demonstrate improved biomechanical performance (i.e. better interfragmentary stability) of the Fixos screws compared to the similar size Synthes HCS with exception of the pull-out strength in the smallest tested screws. However, the smaller diameter of the Ø4.0mm Fixos screw may be more appropriate for certain situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Performance of Cannulated Compression Screws: Fixos Ø4.0, 5.0 & 7.0 mm compared to Asnis III

Introduction: The biomechanical screw performance plays a crucial role on the early interfragmentary stability and, in turn, on the fracture healing outcome. Therefore, this study compares the biomechanical performance of the cannulated headless compression screws Fixos Ø4.0, 5.0 & 7.0 mm to the standard cannulated compression screws Asnis III. Materials & Method: Interfragmentary compression f...

متن کامل

Insertion profiles of 4 headless compression screws.

PURPOSE In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. METHODS The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaph...

متن کامل

Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...

متن کامل

Treatment of scaphoid waist fractures with the HCS screw

The aim of the study was to evaluate the clinical results of the Headless Compression Screw (HCS, Synthes) when used for treatment of acute scaphoid waist fractures. The new screw design generates interfragmentary compression with use of a compression sleeve. Twenty-one patients were treated for acute scaphoid waist fractures type B2 with HCS screws. The average time to the final follow-up exam...

متن کامل

A comparison of plates with and without locking screws in a calcaneal fracture model.

BACKGROUND We compared different plates in an experimental calcaneal fracture model under biocompatible loading. METHODS Four plates were tested: a plate without locked screws (Synthes), and three different plates with locked screws (Newdeal, Darco, Synthes). Synthetic calcanei (Sawbone) were osteotomized to create a fracture model, and the plates were fixed onto them. Seven specimens for eac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014