Effects of Vertical Misalignment of Superconducting Coils in Cyclotrons
نویسنده
چکیده
Introduction The vertical misalignment of coil fields with respect to iron fields in cyclotrons can lead to significant beam losses in the course of beam extraction. During commissioning of the Coupled Cyclotron Project at the NSCL unusually high beam losses have been observed on an extraction magnetic element of the K500 cyclotron. The beam loss was first observed on the beam current profiles measured by the main probe as shown in Fig. 1, where the profile covers the radius ranging from 3 to 31 inches. The rightmost curve in the figure is the current measured at a Faraday cup outside of the cyclotron as the extraction radius of the cyclotron is around 27”. The adjacent curve, which has a flat top around 29”, is the current measured by the main probe between the fourth magnetic focusing bar M4 and the fifth M5 during the beam extraction. The difference of the two curves corresponds to the beam loss. The beam spot at a diagnostic port just outside of the cyclotron was vertically off by about 5 mm. The magnetic elements, which are electrically isolated, can be used to measure the beam current, and revealed that the loss was predominantly at the M5. Radiography was taken on the element after irradiation, and showed a vertical shift of the beam center by 4 mm. Two plausible causes of the beam shift are; 1) superconducting coils displaced from the center of the yoke and pole irons, and 2) extraction elements not vertically centered due to misalignment or due to nonsymmetrical magnetic properties of the steel across the midplane.
منابع مشابه
Design of Ultra-light Superconducting Proton Cyclotron for Production of Isotopes for Medical Applications
A new design has been explored for a superconductingcoil-based compact cyclotron, which has many practical benefits over conventional superconducting cyclotrons. The iron yoke and poles in conventional superconducting cyclotrons have been avoided in this design. The azimuthally varying field is generated by superconducting sector-coils. The superconducting sector-coils and the circular main-coi...
متن کاملIntegration Scheme for SINS/GPS System Based on Vertical Channel Decomposition and In-Motion Alignment
Accurate alignment and vertical channel instability play an important role in the strap-down inertial navigation system (SINS), especially in the case that precise navigation has to be achieved over long periods of time. Due to poor initialization as well as the cumulative errors of low-cost inertial measurement units (IMUs), initial alignment is not sufficient to achieve required navigation ac...
متن کاملMutual Inductance Calculation between Misalignment Coils for Wireless Power Transfer of Energy
In this paper we present a detailed theoretical analysis of lateral and angular misalignment effects in RF coils. Radio-frequency (RF) coils are used extensively in the design of implantable devices for transdermal power and data transmission. A design procedure is established to maximize coil coupling for a given configuration to reduce the effects of misalignment on transmission efficiency. F...
متن کاملMagnetic Force Calculation between Circu- Lar Coils of Rectangular Cross Section with Parallel Axes for Superconducting Magnet
The electromagnetic force between two misaligned coils (coils with parallel axes) with uniform current density distribution and rectangular cross section based on the derived semi-analytical expressions was presented. Using the semi-analytical expressions for magnetic force between filamentary misalignment circular coils we calculate the propulsive and the transverse magnetic force. In order to...
متن کاملEffect of Head Misalignment in Horizontal & Vertical Dimensions on the Magnification Rate of Digital Panoramic Radiography in Different Parts of the Jaws
Background and aim: Considering the widespread development of implants in dental treatment plans, linear measurements on panoramic radiography are of especial importance. In the present study we investigated the effect of head misalignment up to 15° around vertical and horizontal axes on the magnification rate of digital panoramic radiography in each part of upper and lower jaws. Materia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001