A surveillance study of intensity-modulated radiation therapy for postoperative cervical cancer in Japan

نویسندگان

  • Naoya Murakami
  • Hiroyuki Okamoto
  • Fumiaki Isohashi
  • Keiko Murofushi
  • Tatsuya Ohno
  • Daisaku Yoshida
  • Makoto Saito
  • Koji Inaba
  • Yoshinori Ito
  • Takafumi Toita
  • Jun Itami
چکیده

Intensity-modulated radiation therapy (IMRT) was recently introduced to the field of gynecologic malignancies; however, its value is not yet validated. A clinical trial is in preparation to investigate the efficacy and feasibility of IMRT for postoperative cervical cancer. The object of this study was to perform a surveillance study of IMRT for post-operative cervical cancer. A questionnaire regarding the precise methods of conducting IMRT was sent to six institutions that had already introduced IMRT for post-operative cervical cancer, and the data were analyzed. Half of the institutions used static IMRT and the others used volumetric-modulated arc therapy (VMAT). Most institutions used body-immobilizing devices for patient fixation. Most institutions instructed patients to fill their bladder before undergoing planning CT or daily treatment. While one institution inserted metallic markers and another one used radio-contrast-soaked gauze to visualize the vaginal cuff, the other institutions used nothing for vaginal cuff visualization. Most institutions defined the clinical target volumes according to the Japan Clinical Oncology Group or the Radiation Therapy Oncology Group guidelines. Only one institution used a prescribed dose based on 95% of the PTV (D(95)), while the rest used the mean dose (D(mean)). This valuable information from six leading institutions will be utilized in a future prospective clinical trial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Direct Aperture Optimization for Intensity Modulated Radiation Therapy: Two Calibrated Metaheuristics and Liver Cancer Case Study

Integrated treatment planning for cancer patients has high importance in intensity modulated radiation therapy (IMRT). Direct aperture optimization (DAO) is one of the prominent approaches used in recent years to attain this goal. Considering a set of beam directions, DAO is an integrated approach to optimize the intensity and leaf position of apertures in each direction. In this paper, first, ...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2015