Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples

نویسندگان

  • Elham Mohammadhoseini
  • Enayat Safavi
  • Sepideh Seifi
  • Soroush Seifirad
  • Shahram Firoozbakhsh
  • Soheil Peiman
چکیده

BACKGROUND Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. OBJECTIVES To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. PATIENTS AND METHODS 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. RESULTS PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P < 0.001). In samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. CONCLUSIONS In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی وضعیت گازهای خون شریانی در شرایط هیپوباریک و مقایسه آن با شرایط نرمال در خلبانان جنگنده شکاری

Background and purpose : Arterial blood gases ( Arterial blood gas [ABG] ) One of the most important Laboratory tests to determine the status PH the amount of oxygen and carbon dioxide blood levels of bicarbonate. Also, hemoglobin and serum lactate and electrolytes and also won the Test . Height and air pressure can vary on ABG and its surface, low pressure conditions at high altitude pilots pl...

متن کامل

Review of Effect of Storage Time before Freezing on Stem Cells Surveillance, Collected from Cord Blood, Peripheral Blood and Bone Marrow

Introduction: The use of cord stem cells, as a cell source for bone marrow reconstruction in patient under hematopoietic stem cell transplantation is enhancing. The amount of CD34+cells collected from cord blood compared to peripheral blood and bone marrow are less, but their collectionprocesure is easier. Delay in freezing has negative effect on cells surveillance and reduce their ability in ...

متن کامل

Air bubbles and temperature effect on blood gas analysis.

The effect of temperature, time of storage, and presence of air bubbles in specimens for blood gas analysis was studied. The results show that air bubbles in a 10% proportion are undesirable because of significant elevation in the PO2, and the storage of anaerobic blood samples at room temperature (25 degrees C) is acceptable when measurements are done within the first 20 minutes.

متن کامل

The relationship between umbilical artery blood gas analysis and Apgar scores in neonates

  Extended Abstract Introduction and Background : in the first minutes of life it’s important to assess newborn condition very fast but effective and decide about medical intervention as needed. Umbilical artery blood gas analysis and Apgar scoring are the most common assessment systems which studies are trying to more sensitive and accurate way.in this study we compare Apgar scoring system an...

متن کامل

Anesthesia with Propofol in Grass Carp, Ctenopharyngodon idella, and its Effects on Electrocardiogram, Blood Gases and pH

Objective- This study aims to determine the efficacy of propofol in grass carp anesthesia and to examine the impact of the drug on electrocardiogram, pH and blood gases in this fish species. Design- Experimental study. Animals- 120 apparently healthy grass carps, weighting between 1-2 kg. Procedure- Fishes were sorted randomly into 12 groups of 10 fish each. Five groups were anesthetized by bat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015