Dose coverage of axillary level I-III areas during whole breast irradiation with simplified intensity modulated radiation therapy in early stage breast cancer patients

نویسندگان

  • Li Zhang
  • Zhao-zhi Yang
  • Xing-xing Chen
  • Jeffrey Tuan
  • Jin-li Ma
  • Xin Mei
  • Xiao-li Yu
  • Zhi-rui Zhou
  • Zhi-min Shao
  • Guang-yu Liu
  • Xiao-mao Guo
چکیده

PURPOSE This study was designed to evaluate the dose coverage of axillary areas during whole breast irradiation with simplified intensity modulated radiation therapy (s-IMRT) and field-in-field IMRT (for-IMRT) in early stage breast cancer patients. METHODS Sixty-one consecutive patients with breast-conserving surgery and sentinel lymph node biopsy were collected. Two plans were created for each patient: the s-IMRT and for-IMRT plan. Dosimetric parameters of axillary areas were compared. RESULTS The average of mean doses delivered to the axillary level I areas in s-IMRT and for-IMRT plan were 27.7Gy and 29.1Gy (p = 0.011), respectively. The average of V47.5Gy, V45Gy and V40Gy (percent volume receiving≥ 47.5Gy, 45Gy and 40Gy) of the axillary level I in s-IMRT plan was significantly lower than that in for-IMRT plan (p < 0.001). For for-IMRT plans, patients with upper tangential border to humeral head ≤2cm, breast separation >19.3cm and body width >31.9cm had significantly higher mean dose in axillary level I area (p = 0.002, 0.007, 0.001, respectively). CONCLUSION Compared with for-IMRT plan, the s-IMRT plan delivered lower dose to axillary level I area. For centers using s-IMRT technique, caution should be exercised when selecting to omit axillary lymph node dissection for patients with breast conserving surgery and limited positive SLNs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of whole breast radiotherapy is required for safe omission of axillary lymph node dissection in breast cancer patients

Background: The purpose of this study was to assess the dose distribution and coverage of level Ⅰ-Ⅱ axillary lymph nodes during whole breast tangential field radiotherapy (RT) after breast-conserving surgery in patients with breast cancer. Materials and Methods: The level Ⅰ-Ⅱ axillary lymph node volumes were retrospectively contoured by a single radiation oncologist based on computed tomography...

متن کامل

Evaluation of regional nodes irradiation during breast cancer radiotherapy

Background: The purpose of this study was to evaluate nodal irradiation with conventional three-field's technique. Materials and Methods: Fifty patients with breast cancer were enrolled in this study. Computed tomography scans in the supine treatment position were imported into a treatment planning system. Levels I-III axillary and supraclavicular nodes were identified and their depths to the a...

متن کامل

Axillary irradiation in breast cancer; does meticulous contouring make a difference?

Background: Due to the current trends towards replacing axillary dissection with radiotherapy, the need for more precise definition for different nodal stations becomes a must to ensure safe and adequate dose coverage. So, our study aimed to evaluate the coverage of axillary nodal volumes based on Project on Cancer of the Breast (PROCAB) guidelines, for cases previously treated with our standar...

متن کامل

Axillary lymph node dose with tangential whole breast radiation in the prone versus supine position: a dosimetric study

BACKGROUND Prone breast positioning reduces skin reaction and heart and lung dose, but may also reduce radiation dose to axillary lymph nodes (ALNs). METHODS Women with early stage breast cancer treated with whole breast irradiation (WBI) in the prone position were identified. Patients treated in the supine position were matched for treating physician, laterality, and fractionation. Ipsilater...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015