Direct Determination of Selenium in Blood and Urine Samples by Platform Furnace Atomic Absorption Spectrometry

ثبت نشده
چکیده

The problems encountered in platform AAS determinations of selenium in biological fluids were recently reported by Carnrick et al. [1]. The presence of phosphates produces a spectral interference for the selenium determination at 196.0 nm, avoided by using Zeeman background correction. On the other hand, Hoenig and Van Hoeyweghen show that spectral interference of phosphates in animal tissues may be circumvented by using the nickel nitrate matrix modifier and measuring the selenium signal in the peak height mode [6].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Evaluation of electrothermal atomic absorption spectrometry for trace determination of Sb, As and Se in gasoline and kerosene using microemulsion sample introduction and two approaches for chemical modification

Studies aimed at the development of analytical methods based on electrothermal atomic absorption spectrometry for the determination of antimony, selenium and arsenic in gasoline and kerosene were performed. The goal was to develop sensitive methods that allow a simple calibration procedure to be used through direct correlation between analyte signals measured in the sample and signals from aque...

متن کامل

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER

An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010