Comparison of breath‐hold and free‐breathing positions of an external fiducial by analysis of respiratory traces

نویسندگان

  • Sandeep Hunjan
  • George Starkschall
  • Isaac Rosen
  • Karl Prado
  • Naresh Tolani
  • Peter Balter
چکیده

An internal target volume (ITV) accounting for respiratory-induced tumor motion is best obtained using 4DCT. However, when 4DCT is not available, inspiratory/expiratory breath-hold (BH insp, BH exp) CT images have been suggested as an alternative. In such cases, an external fiducial on the abdomen can be used as a substitute for tumor motion and CT images are acquired when the marker position matches - as judged by the therapist/physicist - its positions at previously determined free-breathing (FB) respiratory extrema (FB insp, FB exp). In this study we retrospectively determined the accuracy of these matches. Free breathing 4DCT images were acquired, followed by BH insp and BH exp CT images for 25 patients with non-small-cell lung cancer. Respiration was monitored using a commercial external fiducial system, which generates positional information while CT studies are conducted. Software was written for statistically analyzing the displacement of the external fiducial during BH insp and BH exp CT acquisition and comparing these displacements with corresponding mean FB extrema positions (FB insp and FB exp, respectively) using a Student's t-test. In 72% of patients, mean positions at BH insp differed significantly from mean positions at FB insp (p < 0.05: 0.13 - 1.40 cm). In 92% of patients, mean positions at BH exp differed significantly from mean positions at FB exp (p < 0.05: 0.03 - 0.70 cm), although this difference was smaller than 0.5 cm in many cases (median = 0.34 cm). Our findings indicate that relying solely on abdominal external markers for accurate BH CT imaging in order to accurately estimate FB extrema positions may be subject to significant error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Motivational Abdominal Breathing Device on Breathing Patterns and Shortness of Breath in Patients with Chronic Obstructive Pulmonary Disease

Background and purpose: Despite the high prevalence of chronic obstructive pulmonary disease, There haven,t been definite curative treatment for the disease and focus of treatment has directed towards pulmonary rehabilitation as an effective non-drug treatments. this study were performed to determine the effect of motivational abdominal breathing device on breathing pattern and dyspnea of chron...

متن کامل

The accuracy and effectiveness of self-gating signals in free-breathing 3D cardiac cine MRI

Background Conventional cardiac cine magnetic resonance imaging (MRI) is typically based on the segmented data acquired by breath-hold 2D balanced steady-state free procession (SSFP) pulse sequence [1]. However, the slice misregistration caused by the variation of breath holding positions could compromise the effectiveness of 2D SSFP, and breath-hold makes it difficult for pediatric patients or...

متن کامل

The efficacy of diaphragmatic breathing practice on respiratory function, balance, and quality of life in elderly women

Introduction: Introduction: The respiratory system affects the motor control and stability of the body, especially in the elderly. The present study aimed to determine the effect of diaphragmatic breathing practice on respiratory function, balance, and quality of life in elderly women. Materials and Methods: Forty elderly women with a mean age of 72.40 years participated in this study voluntari...

متن کامل

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Comparison of breath hold and free breathing respiratory triggered retrospectively cardiac gated cine steady-state free precession (RT-SSFP) imaging in adults

Background The cine steady-state free-precession (SSFP) is the standard sequence for left ventricular (LV) function evaluation. However, SSFP mandates uninterrupted RF excitations to maintain steady-state (SS) during suspended respiration. In patients who cannot perform breath-holds (BH), a respiratory triggered (RT) free breathing (FB) retrospectively cardiac gated cine SSFP sequence that driv...