Effectiveness of epicardial atrial pacing using a bipolar steroid-eluting endocardial lead with active fixation in an experimental model
نویسندگان
چکیده
PURPOSE To assess the effectiveness of bipolar epicardial atrial pacing using an active fixation bipolar endocardial lead implanted on the atrial surface in an experimental model. METHODS A total of ten Large White adult pigs underwent pacemaker implantation under general anesthesia. Atrial pacing and sensing parameters were obtained at the procedure, immediate postoperative period and on the 7th and the 30th postoperative in unipolar and bipolar configurations. RESULTS All procedures were successfully performed. There were no perioperative complications and no early deaths. Atrial pacing and sensing parameters for both unipolar and bipolar modes remained stable throughout the study. We observed a progressive increase in atrial thresholds, ranging from 0.49 ± 0.35 (at implantation) to 1.86 ± 1.31 volts (30th postoperative day), in unipolar mode. Atrial impedance measurements decreased slightly over time, ranging from 486.80 ± 126.35 Ohms (at implantation) to 385.0 ± 80.52 Ohms (30th postoperative day). Atrial sensing measures remained stable from the immediate postoperative period until the end of the study. CONCLUSION The bipolar active fixation endocardial lead implanted epicardially can provide stable conditions of pacing and sensing parameters throughout the postoperative follow-up.
منابع مشابه
Endocardial and epicardial steroid lead pacing in the neonatal and paediatric age group.
AIM To compare the performance of steroid eluting epicardial and endocardial leads in infants and children requiring permanent pacing. METHODS Evaluation of pacing and sensing characteristics, impedances, and longevity of 159 steroid eluting leads implanted in 95 children. Group A consisted of 24 children weighing less than 15 kg with 15 endocardial leads (five atrial, 10 ventricular) and 19 ...
متن کاملLong-term follow-up shows excellent transmural atrial lead performance in patients with complex congenital heart disease.
BACKGROUND Many patients with congenital heart disease require permanent pacing for rhythm management but cannot undergo transvenous lead placement. In others, epicardial scarring prohibits adequate sensing and pacing thresholds using epicardial leads. This study describes long-term lead performance using a transmural atrial (epicardial to endocardial) pacing approach in patients with congenita...
متن کاملEquivalent performance of epicardial versus endocardial permanent pacing in children: a single institution and manufacturer experience.
BACKGROUND Children requiring permanent pacing have a lifelong need for follow-up. Epicardial leads have traditionally fared worse than endocardial counterparts. We tested the hypothesis that steroid-eluting epicardial and endocardial leads had equivalent outcomes. METHODS We reviewed medical records of 148 children, mean age 8.2 +/- 4.8 years, in whom a dual-chamber pacemaker system with ste...
متن کاملPermanent epicardial pacing in pediatric patients: seventeen years of experience and 1200 outpatient visits.
BACKGROUND The purpose of this study was to evaluate the long-term outcome of all pediatric epicardial pacing leads. METHODS AND RESULTS All epicardial leads and 1239 outpatient visits between January 1, 1983, and June 30, 2000, were retrospectively reviewed. Pacing and sensing thresholds were reviewed at implant, at 1 month, and at subsequent 6-month intervals. Lead failure was defined as th...
متن کاملNovel Technique of Dual Chamber Pacing Through Mini-thoracotomy and Transatrial Endocardial Active Fixation Lead Insertion for Epicardial Pacing Lead Malfunction
Epicardial pacing lead fixation is employed in patients with cavopulmonary anastamosis (Glenn shunts) when they need permanent pacing. Epicardial pacing in these patients may malfunction due to high pacing thresholds or diaphragmatic pacing. A novel technique of transatrial insertion of two endocardial screw-in pacing leads through right anterolateral minithoracotomy could achieve synchronous a...