Biomechanical Consequences of Coracoclavicular Reconstruction Techniques on Clavicle Strength

نویسندگان

  • Ulrich Spiegl
  • Sean Smith
  • Simon A. Euler
  • Grant Dornan
  • Peter J. Millett
  • Coen A. Wijdicks
چکیده

BACKGROUND Lateral clavicle fractures have been reported after coracoclavicular (CC) ligament reconstructions with bone tunnels through the clavicle. PURPOSE To biomechanically compare clavicle strength following 2 common CC reconstruction techniques with different bone tunnel diameters. STUDY DESIGN Controlled laboratory study. METHODS Testing was performed on 2 groups of matched-pair cadaveric clavicles. Clavicles were prepared with either 2.4-mm tunnels and cortical fixation button (CFB) devices or 6.0-mm tunnels with hamstring tendon grafts (TGs) and tenodesis screws; contralateral clavicles were left intact. A 3-point bending load was applied to the distal clavicles at a rate of 15 mm/min until failure. Ultimate failure load and anterior-posterior width of the clavicles 45 mm medial from the lateral border were recorded. Strength reduction was determined as the percentage reduction in ultimate failure load between paired intact and surgically prepared clavicles. Relative tunnel size was determined as the quotient of tunnel diameter and clavicle width, reported as a percentage. RESULTS The TG technique significantly reduced clavicle strength relative to intact (P = .011) and caused significantly more strength reduction (mean, -30.7%; range, 8.1% to -62.5%) than the CFB technique (mean, -3.8%; range, 34.2% to -28.1%; P = .031). The CFB technique was not significantly different from intact (P = .314). There was a significant correlation between clavicle width and strength reduction (τ = -0.36, P = .04) and between relative tunnel size and strength reduction (τ = 0.51, P = .005). CONCLUSION The TG reconstruction technique with 6.0-mm tunnels, grafts, and tenodesis screws caused significantly more reduction of clavicle strength compared with the CFB technique with 2.4-mm tunnels and CFB device. Additionally, relative tunnel width correlated highly with the strength reduction. CLINICAL RELEVANCE This information can influence intraoperative decision making based on the individual clavicle width and might influence postoperative treatment protocols. Large bone tunnels may predispose patients to clavicle fractures after anatomic CC reconstructions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clavicle Fracture after Coracoclavicular Ligament Reconstruction: A Biomechanical and Finite Element Evaluation of Clavicle Fracture Risk

This open‐access article is published and distributed under the Creative Commons Attribution ‐ NonCommercial ‐ No Derivatives License (http://creativecommons.org/licenses/by‐nc‐nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article w...

متن کامل

Bioabsorbable screw fixation in coracoclavicular ligament reconstruction.

The purpose of this study is to evaluate the biomechanical properties of stainless steel and bioabsorbable screw fixation of the clavicle to the base of the coracoid. Seven matched pairs of fresh frozen shoulders were prepared by removing all soft tissue except the acromioclavicular and coracoclavicular ligament complexes. The shoulders were randomly selected and fixed with 4.5-mm stainless ste...

متن کامل

Anatomic Acromioclavicular Joint Reconstruction With Semitendinosus Allograft: Surgical Technique

Acromioclavicular joint separations are common shoulder injuries in the active patient population. Nonoperative management is recommended for Rockwood type I and II injuries, whereas surgical reconstruction is recommended for type IV and VI separations. The management for type III and V injuries is more controversial and is determined on a case-by-case basis. A multitude of surgical reconstruct...

متن کامل

Biomechanical Evaluation of Hole Diameter for Coracoclavicular Ligament Reconstruction on Coracoid Strength

INTRODUCTION: Many acromioclavicular joint injuries involve damage to the coracoclavicular (CC) ligaments. Some current techniques for CC ligament reconstruction utilize a hole drilled in the coracoid process for placement of a fixation device. Such a hole may increase the probability of coracoid fracture; however, there are no studies in literature that have attempted to evaluate the effects o...

متن کامل

Sports Medicine Anatomic approach to reconstruction of the unstable acromioclavicular joint

Acromioclavicular separation is a common athletic shoulder injury. While many can be treated nonoperatively, high-grade injuries can result in pain and loss of shoulder function. While numerous operative techniques have been proposed, a recent renewed focus on the anatomy of the coracoclavicular ligaments has led to anatomic reconstructive techniques that show promise in biomechanical compariso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014