Co-occurrence of toxic bacterial and fungal secondary metabolites in moisture-damaged indoor environments.

نویسندگان

  • M Täubel
  • M Sulyok
  • V Vishwanath
  • E Bloom
  • M Turunen
  • K Järvi
  • E Kauhanen
  • R Krska
  • A Hyvärinen
  • L Larsson
  • A Nevalainen
چکیده

UNLABELLED Toxic microbial secondary metabolites have been proposed to be related to adverse health effects observed in moisture-damaged buildings. Initial steps in assessing the actual risk include the characterization of the exposure. In our study, we applied a multi-analyte tandem mass spectrometry-based methodology on sample materials of severely moisture-damaged homes, aiming to qualitatively and quantitatively describe the variety of microbial metabolites occurring in building materials and different dust sample types. From 69 indoor samples, all were positive for at least one of the 186 analytes targeted and as many as 33 different microbial metabolites were found. For the first time, the presence of toxic bacterial metabolites and their co-occurrence with mycotoxins were shown for indoor samples. The bacterial compounds monactin, nonactin, staurosporin and valinomycin were exclusively detected in building materials from moist structures, while chloramphenicol was particularly prevalent in house dusts, including settled airborne dust. These bacterial metabolites are highly bioactive compounds produced by Streptomyces spp., a group of microbes that is considered a moisture damage indicator in indoor environments. We show that toxic bacterial metabolites need to be considered as being part of very complex and diverse microbial exposures in 'moldy' buildings. PRACTICAL IMPLICATIONS Bacterial toxins co-occur with mycotoxins in moisture-damaged indoor environments. These compounds are measurable also in settled airborne dust, indicating that inhalation exposure takes place. In attempts to characterize exposures to microbial metabolites not only mycotoxins but also bacterial metabolites have to be targeted by the analytical methods applied. We recommend including analysis of samples of outdoor air in the course of future indoor assessments, in an effort to better understand the outdoor contribution to the indoor presence of microbial toxins. There is a need for a sound risk assessment concerning the exposure to indoor microbial toxins at concentrations detectable in moisture-damaged indoor environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indoor microbiota in severely moisture damaged homes and the impact of interventions

BACKGROUND The limited understanding of microbial characteristics in moisture-damaged buildings impedes efforts to clarify which adverse health effects in the occupants are associated with the damage and to develop effective building intervention strategies. The objectives of this current study were (i) to characterize fungal and bacterial microbiota in house dust of severely moisture-damaged r...

متن کامل

Report Supporting Document ANALYSIS OF FUNGI (MOLD) IN INDOOR ENVIRONMENTS USING FUNGI CULTURABLE METHODS

Fungi are essential components of ecosystems and widely distributed in nature. Fungal spores may be easily dispersed into indoor environments, and if conditions are suitable, some fungal spores may germinate and grow indoors. Mold, a common term for certain filamentous fungi, is fast growing and capable of producing hundreds of thousands of spores in a short period. Mold spores germinate and ra...

متن کامل

Effects of Crowd, smoking, bacterial and fungal infections on COVID-19

The intuition that population density increases the propensity of an epidemic to spread in cities is correct in the sense that increased density likely leads to an increase in the contact rate of an individual, which makes the reproduction number larger and leads to larger infectious disease outbreaks in dense areas. A wealth of research already suggests that smoking suppresses immune function ...

متن کامل

Moisture parameters and fungal communities associated with gypsum drywall in buildings

Uncontrolled excess moisture in buildings is a common problem that can lead to changes in fungal communities. In buildings, moisture parameters can be classified by location and include assessments of moisture in the air, at a surface, or within a material. These parameters are not equivalent in dynamic indoor environments, which makes moisture-induced fungal growth in buildings a complex occur...

متن کامل

Immunotoxic Responses Induced by Streptomyces californicus and Stachybotrys chartarum – The Role of Microbial Interactions

Adverse health effects have been associated with dampness and microbial exposure in buildings, but the possible pathophysiological mechanisms behind these effects are still poorly understood. Although previous studies have shown that certain microbes and microbial components have clear inflammatory and cytotoxic potentials, the complex mixture of microbial species, their spores, metabolites and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2011