Test-Retest Repeatability of Articulatory Strategies Using Real-Time Magnetic Resonance Imaging
نویسندگان
چکیده
Real-time magnetic resonance imaging (rtMRI) provides information about the dynamic shaping of the vocal tract during speech production. This paper introduces and evaluates a method for quantifying articulatory strategies using rtMRI. The method decomposes the formation and release of a constriction in the vocal tract into the contributions of individual articulators such as the jaw, tongue, lips, and velum. The method uses an anatomically guided factor analysis and dynamical principles from the framework of Task Dynamics. We evaluated the method within a test-retest repeatability framework. We imaged healthy volunteers (n = 8, 4 females, 4 males) in two scans on the same day and quantified inter-study agreement with the intraclass correlation coefficient and mean within-subject standard deviation. The evaluation established a limit on effect size and intra-group differences in articulatory strategy which can be studied using the method.
منابع مشابه
Test-retest repeatability of human speech biomarkers from static and real-time dynamic magnetic resonance imaging.
Static anatomical and real-time dynamic magnetic resonance imaging (RT-MRI) of the upper airway is a valuable method for studying speech production in research and clinical settings. The test-retest repeatability of quantitative imaging biomarkers is an important parameter, since it limits the effect sizes and intragroup differences that can be studied. Therefore, this study aims to present a f...
متن کاملRepeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging
Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...
متن کاملHigh SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging
PURPOSE To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). MATERIALS AND METHODS Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the ...
متن کاملEvaluation of Field Map and Nonlinear Registration Methods for Correction of Susceptibility Artifacts in Diffusion MRI
Correction of echo planar imaging (EPI)-induced distortions (called "unwarping") improves anatomical fidelity for diffusion magnetic resonance imaging (MRI) and functional imaging investigations. Commonly used unwarping methods require the acquisition of supplementary images during the scanning session. Alternatively, distortions can be corrected by nonlinear registration to a non-EPI acquired ...
متن کاملRectal cancer
The aim of this study was to evaluate the short-term test-retest reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) parameters of rectal cancer with 3.0T MRI.Twenty-six patients with rectal cancer underwent MRI, including diffusion-weighted imaging with 8 b values. Apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM) parameters (D, pure diffusion; ...
متن کامل