Solutions for biological indicator problems from a quality assurance viewpoint.

نویسنده

  • Wendy Royalty-Hann
چکیده

A biological indicator (BI) is a useful product to confirm sterility assurance after a sterilization procedure. In ISO 11138 and 14161, the concrete procedures regarding the use of BI are described for BI manufacturers and users, respectively. There are several problems involving BI use which must be addressed. These include population verification, D value verification and the general misuse of BI and so on. In this paper, the author will present concrete examples of the above situations and describe how to deal with these problems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sharing Quality Assurance Practice: Issues and Approaches from A Practice-Oriented Knowledge Transfer Model 16 KEYNOTE SPEAKERS Sharing Quality Assurance Practice: Issues and Approaches from A Practice-Oriented Knowledge Transfer Model

Quality Assurance (QA) strategies, frameworks and policies are usually translated into the form of rules and procedures, which provide the basis for QA practices. With the globalisation of higher education efforts are made to improve QA practices through sharing best practices across institutions and internationally. This can be characterised as an example of knowledge transfer through sharing ...

متن کامل

A Hybrid Method Based on Fuzzy AHP and VIKOR for the Discrete Time-Cost-Quality Trade-off Problem

Time, cost and quality are considered as the main components in managing each project. Previous researches have mainly focused on the time-cost trade-off problems. Recently quality is considered as the most important factor in project�s success, which is influenced by time acceleration that is the less time is spent the more success is gained. In time-cost-quality trade-off problems, each act...

متن کامل

Bioanalytical Method Validation: A Quality Assurance Auditor View Point

ISSN:0975-1459 Bioanalytical method validation includes all of the procedures that demonstrate that a particular method used for a quantitative measurement of analytes in a given biological matrix is selective, sensitive, reliable and reproducible for the intended use. Any method developed for the analysis of analytes in biological fluids must yield consistent results despite the variations in ...

متن کامل

Towards Understanding Quality Assurance in Agile Software Development

Agile software development stresses individuals and interaction, customer collaboration, short development cycles and frequent deliveries of valuable software. From the testing and quality assurance viewpoint these principles are challenging, and agile methods seem to lack aspects that traditionally are considered important and fundamental to successful quality assurance. In this paper we ident...

متن کامل

Is Capoeta aculeata (Valenciennes, 1844) a proper Biological indicator for water quality assessment in Khorram-Rud River?

In order to investigate phenotypic abnormality in Khorram-rud River in Lorestan province in Iran, 1982 specimens including 13 species were caught. For this purpose, 8 sites were chosen on Khorram-rud River in Khorramabad city from 10 Km upstream to 10 km downstream of the city. Fish were caught using a cast net. Most of the sampled fish were returned to the river if there were no phenotypic abn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biocontrol science

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2007