Experiences and expectations of a novel X-ray microsource with focusing mirror. I.

نویسندگان

  • A C Bloomer
  • U W Arndt
چکیده

Data are presented from a novel microfocus X-ray generator installed with a choice of ellipsoidal specularly reflecting mirrors. Diffraction data from proteins show the useful flux from this low-power device to be approaching equivalence with that from many far more powerful generators. Intensity measurements show that for small crystals the brilliance is now restricted by the performance of the mirror, which appears to be limited by imperfections in the figure of its surface rather than by a low reflectivity. Suitable choices of ellipsoidal mirror enable the size and divergence of the X-ray beam to be altered readily to match the different requirements of successive samples and appropriate designs are proposed. Alternative types of mirror are expected to be advantageous, especially for the smallest crystals. For crystals of sizes 300 microm or less, which need a small well collimated beam with low divergence, the output from this X-ray tube running at 24 W provides a usable flux similar to that available from rotating-anode generators. The relative performance of this tube and mirror combination becomes increasingly advantageous with the study of ever-smaller crystals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experiences and expectations of a novel X-ray microsource with focusing mirror. I. erratum

The following are corrections to a paper by Bloomer & Arndt [(1999), Acta Cryst. D55, 1672-1680]. The entry in the second row of the I(MAR) column of Table 1(b) on page 1674 should read 6.6 and not 16. 6. In Table 4 on page 1677 the source diameter should be given as 15 &mgr;m and not 15 mm, and the units for the diameter of the sample should be given as &mgr;m instead of mm.

متن کامل

Treatment of the Mirror Foot with Central Ray Resection: Report of 2 Cases

The mirror foot is a rare congenital foot anomaly which is often associated with 6- to 8-toed polydactyly. Postaxial polydactyly is the most common form of this anomaly, while central polydactyly is seen infrequently. We report on 2 cases of the central mirror-foot anomaly. Calcaneus duplication and fibular hypoplasia were present in 1 case. We treated both patients by resecting the middle foot...

متن کامل

Development of focusing mirror for X-ray free electron laser (Reprint from Proceedigns of ISUPEN2011)

We describe the fabrication of a long mirror for focusing hard X-rays to nanometer dimension. We established the figuring system with an accuracy of nanometer-level for X-ray mirror optics. Electrolytic in-process dressing grinding is used for first-step figuring and elastic emission machining is employed for final figuring and surface smoothing. The focusing mirror has an elliptical curved sha...

متن کامل

Novel Semisolid Design Based on Bismuth Oxide (Bi2O3) nanoparticles for radiation protection

Objective(S): The dangerous effects of X-ray have been elucidated by scientific studies in occupational health hygiene.  X-ray protective like an apron, thyroid shield and gloves have been made of lead (Pb) to protect against X-ray. However, such equipment makes a lot of safety and health problems such as toxicity, weight, inflexibility and troubles usage in a physician. To ove...

متن کامل

Introducing a novel Polyvinyl chloride/Tungsten composites for shielding against gamma and X-ray radiations

Introduction: This study introduces a novel polyvinyl chloride (PVC)/tungsten composites with characterization of their shielding properties by employing different techniques. Methods: The PVC/tungsten composites were produced by employing various weight fractions of tungsten micro-particles including 0, 20, and 40 % wt via melt blending method. In the next st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta crystallographica. Section D, Biological crystallography

دوره 55 Pt 10  شماره 

صفحات  -

تاریخ انتشار 1999