Adaptive correction of depth-induced aberrations in multiphoton scanning microscopy using a deformable mirror.

نویسندگان

  • L Sherman
  • J Y Ye
  • O Albert
  • T B Norris
چکیده

We demonstrate adaptive aberration correction for depth-induced spherical aberration in a multiphoton scanning microscope with a micromachined deformable mirror. Correction was made using a genetic learning algorithm with two-photon fluorescence intensity feedback to determine the desired shape for an adaptive mirror. For a 40x/0.6 NA long working distance objective, the axial scanning range was increased from 150 mm to 600 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization-based wavefront sensorless adaptive optics for multiphoton microscopy.

Optical aberrations have detrimental effects in multiphoton microscopy. These effects can be curtailed by implementing model-based wavefront sensorless adaptive optics, which only requires the addition of a wavefront shaping device, such as a deformable mirror (DM) to an existing microscope. The aberration correction is achieved by maximizing a suitable image quality metric. We implement a mode...

متن کامل

Pulse Front Adaptive Optics in Multiphoton Microscopy

The accurate focusing of ultrashort laser pulses is important in multiphoton microscopy, in order to achieve high resolution imaging in biological specimens. Recent advances have shown the improvements to imaging through the inclusion of an adaptive optic element in the microscope. Using a device such as a liquid crystal spatial light modulator or a deformable mirror to modify the wavefront of ...

متن کامل

Adaptive optics two photon scanning laser fluorescence microscopy

Two-photon fluorescence microscopy provides a powerful tool for deep tissue imaging. However, optical aberrations from illumination beam path limit imaging depth and resolution. Adaptive Optics (AO) is found to be useful to compensate for optical aberrations and improve image resolution and contrast from two-photon excitation. We have developed an AO system relying on a MEMS Deformable Mirror (...

متن کامل

hack-Hartmann wavefront-sensor-based adaptive optics ystem for multiphoton microscopy

Hartmann wavefront-sensor-based adaptive optics system for multiphoton microscopy. Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Abstract. The imaging depth of t...

متن کامل

Deep 3D PALM/STORM imaging: MicAO 3DSR – the key to combining depth and highest resolution

Application note www.imagine-optic.com 8 December 2015 – Property of Imagine Optic 1 / 5 The determination of 3D arrangement of cellular structures has become a necessary requirement in cellular biology. Unfortunately, the size of such structures usually lies beyond the diffraction limit and therefore they cannot be visualized in studies using today’s widely popular fluorescence microscopy tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of microscopy

دوره 206 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2002