Meniscal tissue explants response depends on level of dynamic compressive strain.

نویسندگان

  • B Zielinska
  • M Killian
  • M Kadmiel
  • M Nelsen
  • T L Haut Donahue
چکیده

OBJECTIVE Following partial meniscectomy, the remaining meniscus is exposed to an altered loading environment. In vitro 20% dynamic compressive strains on meniscal tissue explants has been shown to lead to an increase in release of glycosaminoglycans from the tissue and increased expression of interleukin-1alpha (IL-1alpha). The goal of this study was to determine if compressive loading which induces endogenously expressed IL-1 results in downstream changes in gene expression of anabolic and catabolic molecules in meniscal tissue, such as MMP expression. METHOD Relative changes in gene expression of MMP-1, MMP-3, MMP-9, MMP-13, A Disintegrin and Metalloproteinase with ThromboSpondin 4 (ADAMTS4), ADAMTS5, TNFalpha, TGFbeta, COX-2, Type I collagen (COL-1) and aggrecan and subsequent changes in the concentration of prostaglandin E(2) released by meniscal tissue in response to varying levels of dynamic compression (0%, 10%, and 20%) were measured. Porcine meniscal explants were dynamically compressed for 2h at 1Hz. RESULTS 20% dynamic compressive strains upregulated MMP-1, MMP-3, MMP-13 and ADAMTS4 compared to no dynamic loading. Aggrecan, COX-2, and ADAMTS5 gene expression were upregulated under 10% strain compared to no dynamic loading while COL-1, TIMP-1, and TGFbeta gene expression were not dependent on the magnitude of loading. CONCLUSION This data suggests that changes in mechanical loading of the knee joint meniscus from 10% to 20% dynamic strain can increase the catabolic activity of the meniscus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IL-1 and iNOS gene expression and NO synthesis in the superior region of meniscal explants are dependent on the magnitude of compressive strains.

OBJECTIVE Partial meniscectomy is known to cause osteoarthritis (OA) of the underlying cartilage as well as alter the load on the remaining meniscus. Removal of 30-60% of the medial meniscus increases compressive strains from a maximum of approximately 10% to almost 20%. The goal of this study is to determine if meniscal cells produce catabolic molecules in response to the altered loading that ...

متن کامل

Dynamic loading enhances integrative meniscal repair in the presence of interleukin-1.

OBJECTIVE Meniscal tears are a common knee injury and increased levels of interleukin-1 (IL-1) have been measured in injured and degenerated joints. Studies have shown that IL-1 decreases the shear strength, cell accumulation, and tissue formation in meniscal repair interfaces. While mechanical stress and IL-1 modulate meniscal biosynthesis and degradation, the effects of dynamic loading on men...

متن کامل

Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate.

The axial and radial compressive moduli of the human meniscus are important material properties in tibiofemoral joint models, but they have not been determined previously for fresh-frozen tissue. Our goals were to measure the moduli at equilibrium and at a physiological strain rate, to determine whether the axial and radial compressive moduli are equal for each type of loading, and to determine...

متن کامل

Regulation of matrix turnover in meniscal explants: role of mechanical stress, interleukin-1, and nitric oxide.

The meniscus is an intra-articular fibrocartilaginous structure that serves essential biomechanical roles in the knee. With injury or arthritis, the meniscus may be exposed to significant changes in its biochemical and biomechanical environments that likely contribute to the progression of joint disease. The goal of this study was to examine the influence of mechanical stress on matrix turnover...

متن کامل

Analysis of 3D strain in the human medial meniscus.

This study presents a method to evaluate three-dimensional strain in meniscal tissue using medical imaging. Strain is calculated by tracking small teflon markers implanted within the meniscal tissue using computed tomography imaging. The results are presented for strains in the middle and posterior third of the medial menisci of 10 human cadaveric knees, under simulated physiologically relevant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Osteoarthritis and cartilage

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2009