Evaluation of Resolving Power and Mtf of Dmc
نویسندگان
چکیده
The present article reports the results of an extensive empirical evaluation of spatial resolution of a digital large format Intergraph DMC sensor. The parameters of the study were flight direction, ground sample distance (GSD) and the distance from the image center. The key finding of the study was that the resolution of the DMC panchromatic large-format image was clearly dependent on the distance from the image center. One reason for this behavior is that the DMC large-format image is composed of four oblique images; the resolution of the oblique images is reduced towards the image border due to the scale reduction and projective distortion. From the image pixel size of 12 μm of DMC, a nominal resolving power value (RP) 84 lines/mm can be derived. Maximal resolution reduction factors in the image corners, caused by the image tilt, were 1.6 in the cross-flight direction and 1.4 in the flight direction. The distance from the image center did not appear to affect the resolution of the low-resolution multi-spectral images looking towards nadir. The observed MTFs indicated attractive behavior. The AWAR values of the panchromatic images were between 61 and 71 lines/mm, which is 1.2-1.4 times the nominal RP-value. Other important findings were the effects of GSD and flight direction on the resolution; these properties evidently characterize the behavior of the entire photogrammetric system tested. The image restoration by a linear restoring finite impulse response filter provided a constant resolution improvement factor of 1.4.
منابع مشابه
Design and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملElectro-Optical Design of Imaging Payload for a Remote Sensing Satellite
Remote sensing using small spacecraft arising from multi-objective economic activity problems is getting more and more developed. These satellites require very accurate pointing to specific locations of interest, with high reliability and small latency. The space borne imaging systems always attempted to achieve the highest ground resolution possible with the available technology at the given t...
متن کاملComparative visual acuity of coleoid cephalopods.
The pelagic realm of the ocean is characterized by extremely clear water and a lack of surfaces. Adaptations to the visual ecology of this environment include transparency, fluorescence, bioluminescence, and deep red or black pigmentation. While the signals that pelagic organisms send are increasingly well-understood, the optical capabilities of their viewers, especially for predators with came...
متن کاملDefocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique
Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...
متن کاملتهیه الکترود یونگزین بر پایه پلی وینیل کلرید برای اندازهگیری دیمتیل آمینو اتیلکلراید هیدروکلراید
Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...
متن کامل