The Use of the Scanning Laser Ophthalmoscope in the Evaluation of Amblyopia

نویسنده

  • David A. Johnson
چکیده

Purpose: The purpose of this study was to evaluate amblyopic patients with scanning laser ophthalmoscope microperimetry to determine whether the scanning laser ophthalmoscope data provide useful information in our understanding of amblyopia and assess its utility in the evaluation of amblyopic patients. Methods: In this retrospective case-series, clinical data of 46 patients with amblyopia were examined after treatment for anisometropic or strabismic amblyopia. Ten normal patients served as controls. All patients were tested with the scanning laser ophthalmoscope, evaluating for the presence of macular scotomata. Scanning laser ophthalmoscope findings were assessed within each group and between groups. Results: A macular scotoma was found in the amblyopic eye of 25 of 26 anisometropic amblyopic patients and all 20 strabismic amblyopia patients. Twenty of 26 patients with anisometropic amblyopia had a relative scotoma in the nonamblyopic eye. All 20 patients with strabismic amblyopia had a nonamblyopic eye scotoma. None of the control patients had a scotoma in either eye. Several clinical features were correlated to scotoma findings within and between groups. Conclusions: The scanning laser ophthalmoscope proved to be a useful tool for the assessment of some features of amblyopia. A scotoma was identified in not only the amblyopic eye of all but one of the amblyopic patients, but also in almost all of the nonamblyopic, presumably “normal” eyes. Thus, ocular effects of amblyopia may not be strictly limited to the amblyopic eye. Trans Am Ophthalmol Soc 2006;104:414-436

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The locus of fixation in strabismic amblyopia changes with increasing effort of recognition as assessed by scanning laser ophthalmoscope.

PURPOSE We performed a qualitative assessment of fixation behaviour in relation to the fovea in patients with strabismic amblyopia. METHODS The fixation of 25 patients with strabismic amblyopia was examined using a scanning laser ophthalmoscope (SLO). A digital frame grabber board was programmed to scan onto the patient's retina single solid black discs of 5, 10 and 15 degrees in diameter and...

متن کامل

Photoreceptor function in unilateral amblyopia

We investigated whether photoreceptor function in amblyopic eyes differed from that in non-amblyopic eyes. Photoreceptor function was assessed with the optical Stiles-Crawford effect (SCE), psychophysical SCE, and foveal visual pigment density in both eyes of ten unilateral amblyopic subjects. Optical SCE and density measurements were carried out with a custom-built scanning laser ophthalmoscop...

متن کامل

Evaluation of the Influence of the Number of Laser Shots on the Characterization of TiO2/MgO Nanocomposites

         The objectives of this work is to synthesize TiO2/MgO nanocomposites using a pulse laser deposition technique. At a vacuum pressure of 2.5 10-2 mBar, TiO2/MgO nanocomposites were synthesized on substrates with a laser power of 600 mJ and a wavelength of 1064 nm. This search utilizes various pulses (500, 600, and 700) at a 6-Hertz repetition rate. X-ray diffraction was utilized to inves...

متن کامل

In vitro Evaluation of Dentin Surface Irradiated by Neodymium-doped: Yttrium Aluminum Garnet Laser (Nd: YAG) Using Scanning Electron Microscopy

Introdouction: Dentinal hypersensitivity (DH) is one of the most painful chronic problems reported in dental offices. Various methods have been applied for the treatment of DH. However, majority of them are either ineffective or last for a short period of time. It has been reported that lasers, particularly Neodymium- doped: Yttrium Aluminum Garnet laser (Nd: YAG), can be helpful in the treatme...

متن کامل

Effect of Cooling on Bending Angle and Microstructure in Laser Tube Bending with Circumferential Scanning

Laser tube bending is a flexible forming process. Two irradiation methods of axial and circumferential scanning are generally used to form metal tubes. The two most important disadvantages of circumferential scanning are its lower bending angle and the time interval required between each scan for cooling purpose. In this research, a novel cooling strategy during laser tube bending with circumfe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007