Fault Tolerant Direct Torque Control of Three-Phase Permanent Magnet Synchronous Motors
نویسندگان
چکیده
The model of three-phase permanent magnet synchronous motor (PMSM) with loss of one phase or loss of one transistor is built and its fault tolerant direct torque control (DTC) is investigated. Extra-leg extraswitch inverter is put to use in the post-fault operation. Two different flux estimators are employed in order to calculate stator flux linkage & their corresponding torque and switching table is kept the same as the case of DTC for the healthy motor. The parameters of PI controller and hysteresis controller are determined by differential evolution algorithm. Dynamic responses of both healthy and unhealthy PMSM DTC system adopting aforementioned two flux estimators are given to compare their performance via simulation and some discussion is presented. The simulation results show the proposed fault tolerant DTC yields satisfactory torque and speed control no matter which one of two flux estimators provided in the paper is employed. Key-Words: Fault tolerant control; Direct torque control; Permanent magnet synchronous motor; Motor model; Flux estimator; Inverter
منابع مشابه
Voltage Control Strategy for Direct-drive Robots Driven by Permanent Magnet Synchronous Motors
Torque control strategy is a common strategy to control robotic manipulators. However, it becomes complex duo to manipulator dynamics. In addition, position control of Permanent Magnet Synchronous Motors (PMSMs) is a complicated control. Therefore, tracking control of robots driven by PMSMs is a challenging problem. This article presents a novel tracking control of electrically driven robots wh...
متن کاملAdaptive Voltage-based Control of Direct-drive Robots Driven by Permanent Magnet Synchronous Motors
Tracking control of the direct-drive robot manipulators in high-speed is a challenging problem. The Coriolis and centrifugal torques become dominant in the high-speed motion control. The dynamical model of the robotic system including the robot manipulator and actuators is highly nonlinear, heavily coupled, uncertain and computationally extensive in non-companion form. In order to overcome thes...
متن کاملAdaptive and intelligent control of permanent magnet synchronous motor (PMSM) using a combination of fuzzy logic and gray wolf algorithm under fault condition
Nowadays, permanent magnet synchronous motors have been widely used in industry due to the elimination of excitation losses, longer life and higher efficiency. Errors in engine and drive systems are unavoidable during operation. Therefore, a suitable scenario should be considered for when these systems fail. If the necessary predictions and control algorithms are not considered for the error co...
متن کاملGeometry optimization of five-phase permanent magnet synchronous motors using Bees algorithm
Among all types of electrical motors, permanent magnet synchronous motors (PMSMs) are reliable and efficient motors in industrial applications. Because of their superiority over other kinds of motors, they are replacing conventional electric motors. On the other hand, high-phase PMSMs are good candidates to be used in certain industrial and military projects such as electric vehicles, spacecraf...
متن کاملOptimum Design of a Five-Phase Permanent Magnet Synchronous Motor for Underwater Vehicles by use of Particle Swarm Optimization
Permanent magnet synchronous motors are efficient motors, which have widespread applications in electric industry due to their noticeable features. One of the interesting applications of such motors is in underwater vehicles. In these cases, reaching to minimum volume and high torque of the motor are the major concern. Design optimization can enhance their merits considerably, thus reduce volum...
متن کامل