PURPOSE Accommodation is a dioptric change in power of the crystalline lens resulting from ciliary muscle contraction that leads to an increase in lens surface curvatures and thickness and changes in the position of lens surfaces. Previous studies have used A-scan ultrasound to measure changes in the position of lens surfaces with voluntary accommodation, but have not simultaneously measured the change in refraction. The goal of this study is to simultaneously measure and correlate refractive and biometric changes in the lens during voluntary accommodation in humans. METHODS Refraction was measured off-axis in the right eye and biometry on-axis in the left eye simultaneously during voluntary accommodation in 22 human subjects between the ages of 21 and 30 years (mean +/- standard deviation: 25.8 +/- 2.3 years). Subjects viewed a distant target and four near targets spanning the full accommodative range available to evaluate refraction and lens surface position at each accommodative state. RESULTS Maximum objectively measured accommodative amplitude of all subjects was 5.64 +/- 0.21 D (mean +/- standard error of mean). Biometric and refractive changes during accommodation were linearly correlated. The mean +/- standard error of mean decrease in anterior chamber depth was 0.051 +/- 0.008 mm/D, increase in lens thickness was 0.067 +/- 0.008 mm/D, and increase in anterior segment length was 0.017 +/- 0.005 mm/D during accommodation. There was a net anterior movement of the lens center of 0.017 +/- 0.005 mm/D. CONCLUSION Anterior chamber depth, lens thickness, and anterior segment length change linearly with refraction during accommodation. Per-diopter changes in the lens were greater in the current study compared with previous studies in which only accommodative demand was measured, which overestimates the accommodative response.
منابع مشابه
The Analysis of Refraction and Accommodation of Extreme Myopia with Cataract after Phacoemulsification and IOL Implantation
Background: To assess the refractive status of cataract patients with extreme myopia and to measure their accommodative capability after monofocal IOL implantation. Design: Prospective non-randomized study conducted at Tianjin Medical University Eye Centre. Participants: 18 patients with 34 extreme myopic eyes (≥-10 Diopter, ≥27mm axial length), and 14 patients with 27 non-myopic eyes that had ...
متن کاملAccuracy of Biometry for Intraocular Lens Implantation Using the New Partial Coherence Interferometer, AL-scan
PURPOSE To compare the refractive results of cataract surgery measured by applanation ultrasound and the new partial coherence interferometer, AL-scan. METHODS Medical records of 76 patients and 104 eyes who underwent cataract surgery from January 2013 to June 2013 were retrospectively reviewed. Biometries were measured using ultrasound and AL-scan and intraocular lens power was calculated us...
متن کاملThe relationship between refractive and biometric changes during Edinger-Westphal stimulated accommodation in rhesus monkeys.
Experiments were undertaken to understand the relationship between dynamic accommodative refractive and biometric (lens thickness (LT), anterior chamber depth (ACD) and anterior segment length (ASL=ACD+LT)) changes during Edinger-Westphal stimulated accommodation in rhesus monkeys. Experiments were conducted on three rhesus monkeys (aged 11.5, 4.75 and 4.75 years) which had undergone prior, bil...
متن کاملDynamic accommodative changes in rhesus monkey eyes assessed with A-scan ultrasound biometry.
PURPOSE Prior studies in humans measured time constants of biometric accommodative changes as a function of amplitude, and prior studies in monkeys used slit lamp videography to analyze dynamic lenticular accommodative movements. Neither of these studies related biometric changes to refractive changes. We wished to develop and test methodology to begin to test the hypothesis that ocular biometr...
متن کاملUltrasonic biometry of myopic eyes in premature children
Background. The aim of our work was to determine changes in opticalanatomical elements of myopic eyes of full-term and premature children during accommodation by means of precise ultrasonic biometry. Materials and methods. The study was made on healthy full-term children’s eyes with emmetropic refraction (group, n = 20); full-term 1st degree myopic children’s eyes with refraction from -1.0 D to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 83 9 شماره
صفحات -
تاریخ انتشار 2006