Whole-blood immunoassay for γH2AX as a radiation biodosimetry assay with minimal sample preparation.
نویسندگان
چکیده
The current state of the art in high-throughput minimally invasive radiation biodosimetry involves the collection of samples in the field and analysis at a centralized facility. We have developed a simple biological immunoassay for radiation exposure that could extend this analysis out of the laboratory into the field. Such a forward placed assay would facilitate triage of a potentially exposed population. The phosphorylation and localization of the histone H2AX at double-stranded DNA breaks has already been proven to be an adequate surrogate assay for reporting DNA damage proportional to radiation dose. Here, we develop an assay for phosphorylated H2AX directed against minimally processed sample lysates. We conduct preliminary verification of H2AX phosphorylation using irradiated mouse embryo fibroblast cultures. Additional dosimetry is performed using human blood samples irradiated ex vivo. The assay reports H2AX phosphorylation in human blood samples in response to ionizing radiation over a range of 0-5 Gy in a linear fashion, without requiring filtering, enrichment, or purification of the blood sample.
منابع مشابه
The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry
Biodosimetry methods, including the dicentric chromosome assay, the cytokinesis-block micronucleus assay and the γH2AX marker of DNA damage are used to determine the dose of ionizing radiation. These techniques are particularly useful when physical dosimetry is absent or questioned. While these assays can be very sensitive and specific, the standard methods need to be adapted to increase sample...
متن کاملBiological Dose Assessment by Chemical Induction of Premature Chromosome Condensation
Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...
متن کاملStudy on γH2AX Expression of Lymphocytes as a Biomarker In Radiation Biodosimetry
Flow cytometry analysis was used to detect the changes of γH2AX protein expression in human peripheral blood lymphocytes. In the dose-effect study, the expression of γH2AX was detected 1 h after irradiation with 60Co γ-rays at doses of 0, 0.5, 1, 2, 4, and 6 Gy. Blood was cultivated for 0, 1, 2, 4, 6, 12, and 24 h after 4 Gy 60Co γ-rays irradiation for the time-effect study. At the same time, t...
متن کاملCytokinesis blocked micronucleus (CB-MN) assay for biodosimetry of high dose accidental exposure
Background: Most of the cytogenetic dosimetry, except Premature Chromosome Condensation assay, saturates at 6 Gy. Present studies are aimed to assess feasibility of simple CB-MN assay for prescreening of high dose accidental exposures. Materials and Methods: Human peripheral blood lymphocytes from two donors were gamma irradiated to different doses ranging from 0-15Gy, cultured for 72 h. Cytoch...
متن کاملRABiT-II: Implementation of a High-Throughput Micronucleus Biodosimetry Assay on Commercial Biotech Robotic Systems.
We demonstrate the use of high-throughput biodosimetry platforms based on commercial high-throughput/high-content screening robotic systems. The cytokinesis-block micronucleus (CBMN) assay, using only 20 μl whole blood from a fingerstick, was implemented on a PerkinElmer cell::explorer and General Electric IN Cell Analyzer 2000. On average 500 binucleated cells per sample were detected by our F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation and environmental biophysics
دوره 54 3 شماره
صفحات -
تاریخ انتشار 2015