Improved FOPDT model estimation with Delayed-relay feedback for constant time dominant processes

نویسندگان

  • Zeinab Tehrani Zamani
  • Behzad Moshiri
  • Ali Khaki Sedigh
  • Alireza Fatehi
چکیده

In this paper with reference to analytical results of different well-known relay feedback methods, we illustrate a main deficiency in parameter estimation of processes with a small ratio of time delay to time constant. Then to rectify this problem we introduce a modified relay feedback structure with additional delay to estimate the parameters of the FOPDT transfer function of the system. The significance of this method lies in the fact that many industrial plants perform fairly such as FOPDT systems, and a wide range of processes have negligible dead time versus their long constant time. Also, the estimated FOPDT transfer function from proposed relay feedback test can be used as a priori knowledge in advanced control strategies which need a FOPDT model of the system. The method is straightforward and simulation results illustrate the effectiveness, and simplicity of the proposed method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relay-Based Autotuning of PID Controller for Improved Load Disturbance Rejection

To overcome sluggish load disturbance response for industrial/chemical processes with slow time constant(s), an improved design for on-line autotuning of proportional-integral-derivative (PID) controller is proposed in this paper, based on relay identification of the widely used first-order-plus-deadtime (FOPDT) process model. Using the fitting conditions established for process response at the...

متن کامل

Improved Autotuning Using Shape Factor from Relay Feedback

The identification of the process plays an integral part in autotuning. The objective of this paper is to formulate an improved autotuning method by thoroughly investigating the shapes of the relay feedback responses and extracting additional information about the process dynamics. The relay feedback tests are conducted on different processes with wide range of dead time to time constant ratio....

متن کامل

Model-based Autotuning System Using Ann and Relay Feedback Test

A model-based autotuning system is presented for PI/PID controllers. A conventional relay feedback test is used to generate the response for estimations of parameters such as: process gain, ultimate gain, ultimate frequency, and apparent deadtime. Two ANNs are built based on the data generated from standard SOPDT processes to enhance the estimation of apparent deadtime. Upon having the estimate...

متن کامل

Estimation of parameters of under-damped second order plus dead time processes using relay feedback

Unknown process parameters are identified using limit cycle data of the relay–response curves obtained from single relay feedback test on second order plus dead time (SOPDT) processes. Time domain analytical expressions of these curves are helpful in deriving conditions to estimate process parameters accurately. Identification algorithms are formulated to estimate minimal number of model parame...

متن کامل

Relay Based Identification of Systems

In this paper, describing functions (DF) of relay with hysteresis is used for identification of systems. Describing function analysis is widely adopted in relay feedback-based identification methods because of the ease of computation involved and the general usefulness of the method. In process control systems, the noises come from measuring devices, control valves or the process itself. Dur in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008