High dose Senna or Poly Ethylene Glycol (PEG) for elective colonoscopy preparation: a prospective randomized investigator-blinded clinical trial

نویسندگان

  • Ahmad Shavakhi
  • Mahsa Kianinia
  • Golara Torabi
  • Amin Nemati
  • Behrouz Saeidian
  • Maryamnaz Hoseinzadeh
  • Faezeh Madjlesi
  • Parsa Navaei
  • Farzaneh Rashidinejad
  • Mohammad Minakari
چکیده

BACKGROUND The aim of this study was to determine the efficacy of two methods of colon preparation for colon cleansing in a randomized controlled trial. METHODS In this prospective randomized investigator-blinded trial, consecutive outpatients indicated for elective colonoscopy were randomized into two groups. Patients in Senna group took 24 tablets of 11 mg Senna in two divided doses 24 hour before colonoscopy. In Poly Ethylene Glycol (PEG) group they solved 4 sachets in 4 liters of water the day before the procedure and were asked to drink 250 ml every 15 minutes. The overall quality of colon cleansing was evaluated using the Aronchick scoring scale. Difficulty of the procedure, patients' tolerance and compliance and adverse events were also evaluated. RESULTS 322 patients were enrolled in the study. There was no significant difference in the quality of colon cleansing, patients' tolerance, compliance and the difficulty of the procedure between two groups (p > 0.05). The incidence of adverse effects was similar between two groups except for abdominal pain that was more severe in Senna group (p < 0.05) and nausea and vomiting that was more common in PEG group (p < 0.05) CONCLUSIONS In conclusion we deduce that Senna has the same efficacy and patient's acceptance as Polyethylene glycol-electrolyte solution (PEG-ES) and it could be prescribed as an alternative method for bowel preparation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Polyethylene Glycol and Senna Bowel Preparation in Dogs on Some Hematological and Serum Biochemical Parameters

Background: Colonoscopy is the preferred procedure for diagnosis of large-bowel diseases in dogs. Polyethylene glycol (PEG) is the most commonly used laxative for colonic cleansing. Senna has been used in traditional medicine as a laxative and an aid to treat constipation. OBJECTIVES: The aim of this study was to evaluate the safety of senna as an alternative or adjunct to polyethylene glycol s...

متن کامل

Comparison of the Efficacy and Safety of Polyethylene Glycol and Senna Solutions in Colon Preparation before Colonoscopy in Dogs

Objective- The aim of this study was to evaluate the efficacy and safety of senna as an alternative or adjunct to polyethylene glycol (PEG) solution in dogs using colonoscopy and radiography.Design - Experimental study.Animals - 20 adult mongrel healthy dogs.Procedures- Dogs were randomly allocated to receive 1 of 4 different bowel preparation regimens including PEG, senna or ...

متن کامل

Polyethylene glycol powder solution versus senna for bowel preparation for colonoscopy in children.

OBJECTIVES Safety and effectiveness of large-volume polyethylene glycol-based solution (PEG-ES) have been documented, but the taste and volume can be barriers to successful colonoscopy preparation. Efficacy and safety of small-volume electrolyte-free (PEG-P) preparation (Miralax) for colonoscopy preparation have been rarely studied, although presently used at many pediatric centers. The primary...

متن کامل

Bowel preparation in children: is polyethylene glycol an answer?

of dose and duration of PEG preparations that will be useful for C olonoscopy is an important diagnostic and therapeutic procedure to evaluate the colon and terminal ileum in children. Anadequatebowelpreparationisnecessaryforcompletevisualization ofboththecolonandterminal ileum.Inadequatebowelpreparationcan lead topoorcolonicvisualization,missed lesions, increasedprocedure time, and possibly a ...

متن کامل

Comparison of the Efficacy and Tolerability between Same-day Picosulfate and Split-dose Polyethylene Glycol Bowel Preparation for Afternoon Colonoscopy: A Prospective, Randomized, Investigator-blinded Trial

BACKGROUND/AIMS In the present study, we evaluated the efficacy and tolerability between same-day bowel preparation protocols using 2 sachets of Picosulfate and a 4 L split-dose polyethylene glycol (PEG) bowel preparation for afternoon colonoscopy. METHODS The study had a single-center, prospective, randomized, and investigator-blinded, non-inferiority design. We evaluated bowel preparation q...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2011