Power Doppler US: evaluation of the morphology of stenoses with a flow phantom.

نویسندگان

  • M Claudon
  • D Winninger
  • S Briançon
  • P Pesque
چکیده

PURPOSE To determine the importance of technical settings at power Doppler ultrasonography (US) for the evaluation of stenoses. MATERIALS AND METHODS A computer-controlled phantom was used to induce a reproducible flow across a calibrated 71% stenosis in an 8.4-mm-diameter tube. Two transducers, 2-4 and 5-10 MHz, working at depths of 3.0 and 11.5 cm, respectively, with different beam angles (40 degrees, 60 degrees, and 90 degrees ), were used to simulate evaluation of pulsatile flow across normal and stenotic vessels in various conditions. For each condition, gain, pulse repetition frequency, and wall filter were progressively turned from low to high values. Two observers measured in a blinded fashion the apparent lumen of the stenotic and normal vessels on longitudinal and transverse images with the use of power Doppler US. RESULTS When the high-frequency transducer was used, gain significantly affected both stenotic and feeding vessel measurement, whereas pulse repetition frequency and filter only affected feeding vessel evaluation. When the low-frequency transducer was used, all factors, including flow velocity and beam angle, played a significant role (P <.001). In most conditions, overestimation of the lumen and underestimation of the lumen of the feeding vessel led to severe underestimation of the degree of stenosis. CONCLUSION Power Doppler US cannot be used to measure stenoses accurately. Underestimation of the degree of the stenosis was significantly higher with the low-frequency probe than with the high-frequency probe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-47: Doppler Ultrasound Diagnosis of Intrauterine Lesions

Background In patients with abnormal uterine bleeding, transvaginal ultrasound (TVS) is the first-line diagnostic approach to exclude endometrial pathology. If a thickened endometrium suggests endometrial pathology, sonohysterography, office hysteroscopy or dilatation and curettage are the second-line tests preferred, depending on availability and on the suspected pathology, to exclude malignan...

متن کامل

Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs

Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...

متن کامل

Very different performance of the power Doppler modalities of several ultrasound machines ascertained by a microvessel flow phantom

INTRODUCTION In many patients with rheumatoid arthritis (RA) subclinical disease activity can be detected with ultrasound (US), especially using power Doppler US (PDUS). However, PDUS may be highly dependent on the type of machine. This could create problems both in clinical trials and in daily clinical practice. To clarify how the PDUS signal differs between machines we created a microvessel f...

متن کامل

Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry

Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome  by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...

متن کامل

ارزیابی نقش سونوگرافی کالر داپلر در پیش بینی میزان موفقیت روش‌های غیرجراحی در جااندازی انواژیناسیون روده‌ای

  Background & Aims: Intussusception is one of the most common causes of bowel obstruction in young children ultrasonography (US) is considered a reliable method for diagnosis. The primary treatment is hydrostatic radiologic reduction, but this should never be used in children with necrotic or perforated bowel. Clinical and radiologic prediction of intestinal necrosis is difficult. Color Dopple...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 218 1  شماره 

صفحات  -

تاریخ انتشار 2001