Anatomical and clinical study on effects of sonography with pulse inversion and microbubble contrast in rabbit kidney.

نویسندگان

  • Biagio Valentino
  • Giuseppe Caruso
  • Elvira Farina Lipari
  • Diego Lipari
  • Antonella Campisi
  • Giuseppe Salvaggio
  • Roberto Lagalla
چکیده

Aim of the present study was to evaluate by transmission electron microscope (TEM) modifications in rabbit kidney-parenchyma after submission to ultrasound contrast agent (UCA) with Pulse Inversion Harmonic Imaging (PIHI). Seven inbred male albino rabbits were divided into three groups: 1) control group (n = 1 animal); 2) sonicated group (n = 3 animals); 3) sonicated group with UCA injection (CEUS) (n = 3 animals). The first group was not exposed to ultrasonography (US) and/or UCA. The second and third groups underwent baseline US and later to US with PIHI with a high mechanical index; in the third group UCA was simultaneously administered. Ultrastructural studies and image analysis were blindly performed on 50 samples (2mm3), including cortex and medulla, by two experienced pathologists with TEM. By TEM observations of the first and second groups showed no structural modifications of renal cortex and medulla. TEM observations of the third group showed ultrastructural changes of renal corpuscle, proximal and distal convoluted tubules and collecting tubules; further in the most of observed sections the filtration membrane had an alteration of typical trilaminar pattern and vacuolisation of glomerular endothelial cells with irregular edges. Therefore in rabbit kidney submitted to CEUS some ultrastructural modifications were observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Comparison of contrast-enhanced fundamental imaging, second-harmonic imaging, and pulse-inversion harmonic imaging.

RATIONALE AND OBJECTIVES To investigate the feasibility of recent contrast-specific ultrasound techniques in depicting vascular flow and the effects of changing the output power of the transducer and insonation mode on contrast enhancement, the authors performed an experimental study with a flow phantom. METHODS While changing the mechanical index and the sound insonation mode (continuous and...

متن کامل

Pulse Inversion Imaging of Liver with Microbubble Contrast: Improved Characterization of Tumoral Vasculature in Focal Hepatic Lesions

The challenge presented to ultrasound imaging technology by the advent of microbubble contrast agents is to create a method that detects the echoes from bubbles in preference to the echoes from tissue. Recent progress in ultrasonography is represented by the development of harmonic and pulse inversion imaging (Fig. 1, 2). Pulse inversion imaging is a newly developed one, which uses the full ban...

متن کامل

بررسی سونوگرافیک تومورهای سولید کلیه

ABSTRACT: Solid tumors of adult kidney are the most malignant tumors of human body After bladder tumors, they are the commonest solid tumors of urinary tract. There is a tendency to study these lesions by modalities other than sonography and for this reason there are some doubts in studying these tumors by sonography. For resolving these doubts , the first step is to reveal the different son...

متن کامل

Ultrasonographic Evaluation of the Urinary System in New Zealand White Rabbit and Tolai Hare

Ultrasonographic examination of urinary system (kidney and urinary bladder) was conducted in New Zealand white rabbit [NZwr] and Tolai hare (Lepus tolai). Ultrasound images of the kidney and urinary bladder were evaluated on fifteen healthy rabbits of New Zealand white rabbit and another fifteen Tolai hares. The healthy rabbits were 8-12 months old (mean = 9.3 months), of both sexes and weighed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Italian journal of anatomy and embryology = Archivio italiano di anatomia ed embriologia

دوره 113 3  شماره 

صفحات  -

تاریخ انتشار 2008