Backscattering factor for some personal dosimeters and impact on Hp\(10\)

نویسندگان

  • V. P. SINGH
  • N. M. BADIGER
  • R. R. BIHARI
چکیده

In the present paper, we estimated backscattering factors for the TLD and active personal dosimeters using 662 keV gamma-ray photons on a PMMA surface, which are, for the TLD, 1.12; Dosicard, 1.116; DRD, 0.99; and Saphydose, 1.073, and on a water slab phantom surface; for the TLD, 1.115; Dosicard, 1.112; DRD, 1; and Saphydose, 1.059. The backscattering factor contribution for the Saphydose is nearly half that of the TLD and Dosicard, whereas it is zero for the DRD. The DRD underestimates Hp(10) by 10.3–11.6%, whereas for the Saphydose it is 3.4–5% compared with the TLD or Dosicard. The response of the DRD to Hp(10) is nearly independent of the phantom, whereas the TLD, Dosicard and Saphydose require phantoms for calibration for personal monitoring. It is observed that the PMMA phantom contributes slightly higher backscattering compared with the water slab phantom. The backscattering factor of the selected dosimeters is comparable with ICRU tissue already reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE

Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among  different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...

متن کامل

Response of TLD and RPL personal dosimeters in a national inter-comparison test program

Background: Different kinds and models of personal dosimeters are used in individual monitoring by workers.  Performance testing as part of approval procedures is carried out to demonstrate that the essential performance specifications are routinely maintained. There are four service providers in Iran which use different luminescence techniques (i. e. TLD and RPL) with various kinds of dos...

متن کامل

Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran

Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...

متن کامل

ارزیابی ضرورت به‌کارگیری دزیمتر فردی در رادیولوژی دندان

Lowness of the registered doses by the personal dosimeters (film badge in Iran) for most of dental radiology practitioners has made some of them doubtful about the rightness of the employed dosimetry method. On the other hand, some relatively considerable occupational exposures in dental radiology have been reported. These two opposite facts propose a comprehensive statistical and analytical re...

متن کامل

Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000